with. the. system. cold,. must. be. between. 1 
and 1.5 bar..
NB:  The  "T"  versions  the  loading  is  done 
by  loading  tap  externally  mounted  by  the 
installer.
2.4.1 
System draining (fig. 4)
To.drain.the.system,.turn.off.the.boiler.and.
use.the.discharge.valve.(7).
2.5 
INSTALLATION OF 
COAXIAL DUCT
ø 60/100 - ø 80/125 (fig. 6)
The. axial. suction. and. discharge. pipes. are.
supplied. in. a. special. kit. (that. can. be. pur-
IMPORTANT:
-   T he  insertion  of  each  additional  90° 
bend with a diameter of  60/100 reduces 
the available section by 1.5 meters.
-   T he  insertion  of  each  additional  90° 
bend with a diameter of 80/125 reduces 
the available section by 2 meters.
-   E ach  additional  45°  curve  installed 
reduces  the  available  length  by  1.0 
metres.
- During assembly it is important to make 
sure  that  the  kit  with  axial  pipes.  (1)  is 
positioned horizontally.
NOTE
Before  connecting  accessories,  it  is 
always advisable to lubricate the internal 
part of the gaskets with silicon products. 
Avoid using oils and greases.
Model 
Length of pipe 
L 
12 T.
6.m.
25 / 25 T.
6.m.
30 / 30 T.
5.m.
35 / 35 T.
4.m.
LIST OF ø 60/100 ACCESSORIES
Coaxial.duct.kit.code
1.
Extension.L..1000.code
2a.
Extension
2b.
.L..500.code.8096151
Vertical.extension
3.
Additional..90°.curve.code.
4a.
Additional..45°.curve.code
4b.
Tile.for.joint.code
5.
.
Terminal.for.roof.exit.L.
6.
.
82
chased. separately). along. with. assembly.
instructions.
The.diagrams.of.fig..6.illustrate.some.exam-
ples. of. different. types. of. discharge. modali-
ties.allowed.and.the.maximum.lengths.that.
can.be.reached.
2.6 
INSTALLATION OF SEPARATE  
DUCTS ø 80 - ø 60 (figg. 7-8)
The. kit. with. dedicated. pipes. enables. to.
separate. the. exhaust. fumes. pipes. from. the.
air.suction.pipes.(Fig..7):.
-.The. kit. with. dedicated. ø. 80. pipes,. code..
8089912,.includes.a.SUCTION DIAPHRAGM 
THAT IS NOT.used.for.these.models..To.be.
able.to.use.the.air.tap,.cut.its.base.with.a.
tool.(A).and.assemble.it.(B).
2
y
Length of pipe
ø 60/100 
ø 80/125
          H  
L 
          H
Min 
Max 
Min 
1.3.m.
8.m.
12.m.
1.2.m. 15.m
1.3.m.
8.m.
12.m.
1.2.m. 15.m
1.3.m.
7.m.
10.m.
1.2.m. 13.m
1.3.m.
6.m.
8.m.
1.2.m. 11.m
.8096250
.8096150
with.coupling.code
.L..140.
.8086950
.8095850
..8095950
.8091300
.1285.code.8091205
x
2
4
3
C43
x.+.y.=..L.(m)
1
Max
C13
LIST OF ø 80/125 ACCESSORIES
Coaxial.duct.kit.code
1..
Extension
2a.
.L..1000.code.8096171
Extension
2b.
.L..500.code.8096170
3.
Adapter.for
.ø.80/125.code.8093150
4a.
Additional..90°.curve.code
4b.
Additional..45°.curve.code
5.
Tile.for.joint.code
.8091300
6..
Terminal.for.roof.exit.L.
-.The. kits. with. dedicated. ø. 60. pipes,. code.
8089913,. include. a. suction. collar. that.
replaces.the.boiler.collar.(C)..
It.is.now.possible.to.insert.an.expansion.or.
bend. in. polypropylene. without. gaskets. or.
sealant.
The  maximum  overall  length,  resulting 
from the sum of all the suction and dischar-
ge pipes, is determined by the load losses 
of  the  single  connected  accessories  and 
should not exceed 10 mm H
O (version 12) - 
2
15 mm H
O (version 25-30-35) (ATTENTION: 
2
the  total  length  of  each  pipe  should  not 
exceed 25 m, even if the total loss is below 
the maximum applicable loss.)
See.Table 1-1/a.for.information.on.the.load.
losses. of. single. accessories. and. the. exam-
ple.of.Fig..8.for.information.on.how.to.calcu-
late.load.losses.
6
5
2
3
C33
L.(m)
2
1
.8096253
.8095870
.8095970
.1285.code.8091205
Fig..6

Publicidad

loading

Este manual también es adecuado para:

Murelle he 25 t erpMurelle he 30 t erpMurelle he 35 t erp