Specifications
Dimensions - Indoor Models
6" W x 9" H x 3" D
(15.3 cm W x 22.9 cm H x 7.6 cm D)
Dimensions - Outdoor Models
6" W x 9" H x 4" D
(15.3 cm W x 22.9 cm H x 10.2 cm D)
Power Specifications:
Indoor Models - Domestic
Plug-in Transformer, Class 2, UL Listed,
CSA Certified (or equivalent)
• Input: 120 V a.c. 50/60 Hz, 0.5 Amps
• Output: 24 V a.c. 50/60 Hz, 20 VA
Outdoor Models - Domestic
Built-in Transformer, Class 2, UL Listed,
CSA Certified (or equivalent)
• Input: 120 V a.c. 50/60 Hz, 0.5 Amps
• Output: 24 V a.c. 50/60 Hz, 20 VA
Indoor Models - Export
Plug-in Transformer, TUV Approved
• Input: 230 V a.c. 50 Hz, 0.1 Amps
• Output: 24 V a.c. 50 Hz, 20 VA
Outdoor Models - Export
Built-in Transformer, TUV Approved, SAA Approved
• Input: 230/240 V a.c. 50/60 Hz, 0.1 Amps
• Output: 24 V a.c. 50/60 Hz, 20 VA
Indoor Models - Australia
Plug-in Transformer, SAA Approved
• Input: 240 V a.c. 50 Hz, 0.1 Amps
i
• Output: 24 V a.c. 50 Hz, 20 VA
Maximum Load Per Station:
0.4 Amps @ 24 V a.c.
Maximum Load For Pump/Master Valve:
0.4 Amps @ 24 V a.c.
Total Maximum Output: One station plus pump,
not to exceed 0.80 Amps @ 24 V a.c.
Temperature Limit Range:
Operating – 14°F to 140°F (-10°C to 60°C)
Storage – -22°F to 149°F (-30°C to 65°C)