Procedure valid for GAS CONVERSION
– go into the parameter section by pressing the buttons
and
o
(approximately 5 seconds) at the same time until
"tS"
(installer) appears on the 2 digits of the display which
alternate with "0.1" (parameter number) and a "2" (set value)
holding the buttons
NOTE:
scrolling movement. Pressing the button
scroll through the previous parameters.
– keep the button
>
pressed and scroll through the parameters
until reaching parameter "0.3"
– press the button
o
to confirm (approximately 3 seconds) and
access the default value which is flashing
– press the button
>
and select "1" (LPG)
– press the button
o
for at least 3 seconds to confirm the
modification. the value will stop flashing.
Procedure which MUST be carried out after:
– the nozzles for gas conversion
– changing the gas valve following a fault
– changing the the electronic board following a fault
– electrode
– fan
– burner
– go into the parameter section (if not already there) by pressing
the buttons
<
and
o
(approximately 5 seconds) at the same
time until "tS" (installer) appears on the 2 digits of the display
which alternate with "0.1" (parameter number) and a "2" (set
value)
– keep the button
>
pressed and scroll through the parameters
until reaching parameter "tS 4.9"
– press the button
o
to confirm (approximately 3 seconds) and
access the default value which is flashing
86
>
or
<
increases the speed of the
<
allows the user to
– press the button
>
or
<
– press the button
o
stop flashing
– keep the button
>
pressed and scroll through the parameters
until reaching parameter "tS 7.0"
– press the button
o
access the default value which is flashing
– press the button
>
or
– press the button
o
stop flashing
– exit the parameter section by pressing and holding down the
buttons
<
and
o
at the same time
until the delivery temperature is displayed.
m
IMPORTANT
To complete this task the user MUST carry out the
following procedure.
<
to set the value at "49"
to confirm the modification The value will
to confirm (approximately 3 seconds) and
<
to set the value "5"
to confirm the modification The value will
(approximately 5 seconds)