SL24.W
CL 1
-
OPED
PP
LRNA
CPED
-
OPC1
-
CLC1
-
-
END
Self-calibration:
If the gate travel parameter is changed, there is no need
for the installer to run new calibrations, however, when
changing the travel parameters, the control panel needs
to learn the current curve again, thus disabling the obsta-
cle detection only during the self-calibration manoeuvre.
Self-calibration is appropriately signalled:
- on the control panel display by the code AT
- by the light flashing at twice the normal frequency
The events generating self-calibration are:
- change in parameters: T24, T26, T28, T30, T32, T34,
T40
- loading of settings from a MEM.W memory card
- reset/import of settings from the Wi-Gate app
Gate travel parameters
Sub
Description
menu
Motor force (%).
Sets the value of the force given to
the motor to push the leaf
T1
Minimum force
Maximum force
Direction.
Sets the motor direction
Left actuator (the gate seen from
the side where the actuator is
T4
installed opens towards the left)
Right actuator (the gate seen
from the side where the actuator is
installed opens towards the right)
16
Continuation of open-
ing and slowdown
speed up to closing
limit switch
Start pedestrian
opening.
When button
pressed: pedestrian
opening position
setting
Leaf closing from
pedestrian opening
position
Opening current
reading
Closing current
reading
End of procedure
Values
(default)
(50)
1
100
(1)
1
2
EN
Choice of intervention method
for obstacle detection
Overcurrent or leaf stopped:
the obstacle is detected when the
current threshold or the encoder
slowdown threshold is exceeded
Leaf stopped: the obstacle is
detected only when the leaf slows
down excessively
T7
Overcurrent: the obstacle is de-
tected when the current threshold
is exceeded
Overcurrent and leaf stopped:
the obstacle is detected when the
current threshold and the encoder
slowdown threshold are exceeded
at the same time
Motor obstacle detection time
on opening
Time after which the current
threshold or the encoder threshold
trigger the obstacle detection on
T8
opening (adjustable at intervals of
100 ms)
100 ms (minimum time)
600 ms (maximum time)
Motor obstacle detection time
on closing
Time after which the current
threshold or the encoder threshold
trigger the obstacle detection on
T9
closing (adjustable at intervals of
100 ms)
100 ms (minimum time)
600 ms (maximum time)
Polling time
Time during which the motor push-
es with maximum force to move
the leaf (adjustable at intervals
T12
of 0.5 s)
0.5 s (minimum time)
5.0 s (maximum time)
Pedestrian opening position (%
of total opening travel)
T13
Minimum space
Maximum space
Disengagement space on obsta-
cle (inversion distance following
the detection of an obstacle)
T14
Not disengaged, stops only
Minimum inversion
Maximum inversion
(1)
1
2
3
4
(20)
10
60
(20)
10
60
(2.0)
0.5
5.0
(30)
10
100
(5)
OFF
1
10