2.7 Thermal safety cut-out

A thermal safety cut-out is incorporated in the fan stove to prevent damage due to overheating. This
can happen if the heat outlet was restricted in any way or if the chimney flue has not been blocked
off effectively. If the cut-out operates, unplug the stove from the socket outlet and
allow approximately 10 minutes before reconnecting. Before switching the stove back on remove any
obstruction that may be restricting the heat outlet, then continue normal operation.

2.8 Maintenance

WARNING: Always remove the plug from the wall socket before performing maintenance.

2.8.1 Replacing lights

If a large quantity of smoke is grey or colourless it is possible that one or more lights is not burning.
You can check this as follows.
1. Pull the drawer while the flame effect is active. (See Fig. 3).
2. Look at the lights from a distance to see which light(s) are broken.
3. Put the main switch in the "OFF" position, and remove the plug from the wall socket.
4. Leave the appliance like this during 20 minutes so that the lights can cool down before
removing them.
5. Remove the water tank by lifting it up and to the front and put it in a sink.
6. Remove the collection reservoir as described in chapter 2.9.2 .
7. Remove the broken light(s) by pulling it from its holder (see Figs. 5 and 6). Replace the light
by a Dimplex Opti -opti-myst, 12V, 50W, basis Gu 5.3, 8º radiation angle, coloured light.
(obtainable from your dealer).
8. Gently push the light(s) with the 2 pins in the corresponding holes (See Figs. 5 and 6).
9. Put the collection reservoir and the water tank back in their positions.
10. Put the plug in the wall socket and put the main switch in the "ON" position.
2.8.2 Filling the water tank.
When you use the appliance for the first time or when you hear two beeps and the lights have gone
out the water tank needs refilling.
Proceed as follows.
1. Put the main switch in the "OFF"(0) position.
2. Open the drawer. (See Fig. 3).
3. Remove the water tank by lifting it up.
4. Put the water tank in the sink and open the cap. (See Fig. 7).
5.
Fill the water tank with water with a hardness as indicated in chapter 2.2.
6. Screw the cap back on.
7. Put the water tank back in with the cap facing down and the flat side on the front.