Product Manual
2.9.2 Sauna heaters safety clearances
Minimum distances for the
mounting bracket (mm)
Drill. Ø3,5 mm
Effect
Sauna room
Volume
min.
max.
kW
m³
m³
4,5
3
6
6,0
5
9
8,0
8
12
9,0
9
13
Table. 1 Safety clearances
Effect
kW
4,5
6,0
8,0
9,0
Table. 2 Heater connection cable and fuse
Havanna STS
(mm)
A
475
min
30
min
20
K
280
B
Image 3 Safety clearances
Heaters minimum clearance (mm)
Height
Side
In front of
wall
A
min. mm
mm
mm
1900
40
80
1900
45
100
1900
75
130
1900
80
150
Heater connection cable
400V - 415V 3N~
(mm)
A
300
D
min
30
min
20
Screw 6 x 40 (2 kpl)
Screw 6 x 16 (2 kpl)
To the
To ceiling
floor
D
K
mm
mm
1100
120
1100
120
1100
150
1100
150
H07RN –F/ 60245 IEC 66
mm²
5 x 1,5
5 x 1,5
5 x 2,5
5 x 2,5
Stone
min.
max.
Approx
Approx
B
J
kg
kg
mm
mm
135
245
20
28
140
245
20
35
170
275
20
35
175
275
20
35
Fuse
A
3 x 10
3 x 10
3 x 16
3 x 16
9