3.1 Technical data
Ambient temperature
Relative humidity
Tab. 1
Ambient conditions during operation
Storage in a closed environment, ambient
temperature
Ambient temperature for shipment
Relative humidity
Tab. 2
Ambient conditions for transport and storage
®
ABIPLAS
CUT
Type of wear parts
Application process
Type of use
Pilot current
Rated current and corresponding duty cycle
Type of gas
Operating pressure (flow pressure)
Torch inlet pressure
Plasma air
Air flow rate measured with 1.8 mm nozzle bore
Soft start
Gas post flow delay
Type of voltage
Type of ignition
Max. arc inflammability and stabilisation voltage
Breakdown voltage 50 Hz
Voltage rating
Protection type of the device connections
(EN 60529)
Control device in the torch handle
Tab. 3
Product-specific torch data (EN 60974-7)
1Special wear parts are for ignition-critical power sources and labelled with an 'X'.
BAL.0120 • 2019-01-03
3 Product description
−10 °C to +40 °C
Up to 90% at 20 °C
−10 °C to +40 °C
−25 °C to +55 °C
Up to 90% at 20 °C
200 W
200 W MT
Standard
Plasma cutting/gouging
Manual/automatic
15–27 A (max. 29 A)
200 A/100%
Compressed air
3.5–4.5 bar
Approx. 39 l/min
≥15 l/min
> 20 sec
DC direct voltage
HF
7 kV
Peak value of 500 V
IP3X (200 W)
IP2X (200 W MT)
For 42 V and 0.1 to 1 A
1
Special
160 A/100%
3.5 bar
Approx. 21 l/min
If available
≤15 l/min
EN - 5