System set-up
• G/W number and outdoor unit number
Enter the number.
For the G/W number, you can set it from the entered information from the existing [G/W information].
Also the outdoor unit number cannot be duplicated within the same G/W number and must be within the range
of (0-7).
When you pressed the default button, it succeeds the higher G/W information and automatically generates the
values.
Module type selection
• UAC : Integrated air conditioner (MultiV PLUS , MPS product , others applied with LGAP)
Note : SGL for special model , Don t select SGL
• Maximum power consumption
Set it according to each model manually.
By setting the maximum power consumption value of the air conditioner, the system limits the power
consumption within the set limit.
Note1: For peak control, you must enter the maximum power consumption for each indoor unit
Note2 : Indoor power consumption set method
Power consumption of nth indoor unit =
(Outdoor unit power consumption + Total indoor unit power consumption) x
(3) Group entry window
You can enter from the top row for all entry windows
• When adding a group : When you click on the window, you will see the yellow entry
• When editing the group : Select the group to edit and make changes.
• When deleting the group: Select the group to delete and delete the name.
•
30 PC Central Controller
CAUTION
When you delete a group, the information of all indoor units under the specific
group will be deleted.
: Default entry
Based on the gateway information and outdoor unit information set above,
default values are automatically entered for a maximum number of indoor
units.
window.
Enter the group number. The group number is automatically
entered in series.
Power consumption of nth indoor unit
Total indoor unit power consumption