2 / INSTALLING YOUR APPLIANCE
• • ELECTRICAL CONNECTION
Your hob must be connected to a 220-240 V~
single phase mains supply via a standard
IEC 60083 2 pole + earth electrical plug or
connected to an all-pole cut-off device, in
compliance with the current installation regu-
lations.
The electrical plug must remain accessible after
installation.
Note
— The safety wire (green and yellow) is connected to the appliance's earth terminal
must be connected to the mains earth terminal
— If the power cable is damaged, it should be replaced by the manufacturer, its after-sales service
department or by a similarly qualified person in order to avoid danger.
C
ROSS-SECTION OF CABLE TO BE USED
H05V2v2f cable
Cross-section of
conductors in mm²
Fuse
.
41
EN
220-240 V ~ - 50 Hz
3 conductors,
including 1 one
earth wire
1
10A
and