Basic Operation
UPS ON/OFF
• Plug the UPS into a live, grounded outlet.
The green
LED will illuminate, the battery charger will engage as necessary and the SURGE PROTECTED outlets will begin passing power.
• Plug equipment into the UPS: You will overload the UPS if the total volt-amp (VA) ratings for all the equipment connected to the BATTERY/
SURGE PROTECTED outlets exceed the UPS output capacity. To find your equipment's VA ratings, look on their nameplates. If the equipment
is listed in amps (A), multiply the number of amps by 120 to determine VA. For example: 1A × 120 = 120VA.
• Turn the UPS on: Press the power button
passing AC line power. The UPS will automatically recharge internal batteries as needed. Once turned on, your UPS is ready to protect
connected equipment from blackouts, brownouts, overvoltages and transient surges.
• Turn the UPS off: Press the power button
LED Indicators
Description
Line Mode
Battery Mode
Battery Low
Overload Alarm - Line Mode
Overload Alarm - Battery Mode
Overload - Line Mode
Overload - Battery Mode
Replace Battery
Fault Condition
. The UPS alarm will beep once briefly. The BATTERY/SURGE PROTECTED outlets will begin
.
Online
LED (Green) Battery
On
Off
Flashes Every 10 Seconds
Off
Flashes Every 1 Second
On
Off
Flashes Every 1 Second
Off
Off
On
Off
LED (Amber)
Fault
Off
Off
Off
Off
Off
Flashes Every Minute
Off
4
Alarm
LED (Red)
Off
Off
Off
Off
On
Sounds Every 1 Second
Off
Sounds Every 0.5 Second
Off
Sounds Every 0.5 Second
On
Sounds Continuously
Off
Off
Sounds Every Minute
On
Sounds Continuously