En: Installation Sheet - UTC Fire & Security Interlogic EV1116 Series Hoja De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 11
7
(1)
EV1116
J4
J3
CP
Normal
< 33 Ω
A
larm
EV1116
( ) 2
J4
J3
CP
Normal
4.7 k
A
larm
9.4
kΩ
Tamper
Short
0

EN: Installation Sheet

Introduction
The EV1116 series includes the EV1116 and EV1116AM PIR
motion sensors. They have a patented mirror, pyro and signal
processing technology.
Note:
EV1116AM has not been evaluated by UL.
Installation guidelines
The technology used in these detectors resists false alarm
hazards. However, avoid potential causes of instability (see
Figure 1) such as:
Direct sunlight on the detector
Strong draughts onto the detector
Heat sources within the detector field of view
Animals within the detector field of view
Obscuring the detector field of view with large objects,
such as furniture
Objects within 50 cm (20 in.) of the anti-masking (AM)
detector
Installing two detectors facing each other and less than
50 cm (20 in.) apart (only AM detectors)
P/N 146251999-4 (ML) • REV D • ISS 12MAR13
J4
J3
J4
J3
J4
J3
Normal
4.7 k
A
larm
9.4
kΩ
Tamper
Short
0
EV1116AM
J4
J3
CP
Normal
< 33 Ω
A
larm
EV1116AM
J4
J3
CP
Normal
4.7 k
A
larm
9.4
kΩ
Tamper
Short
0
AM/TF
Installing the detector
Figure 7 legend
Item
Description
(1)
Standard connection (factory default)
(2)
Dual loop connection
CP
Control panel
WT
Walk test
AM
Antimasking
D/N
Day/night
Rtest
Remote test
To install the detector:
1.
Lift off the custom insert and remove the screw
(see Figure 2, step 1).
2.
Using a screwdriver, carefully prise open the detector (see
Figure 2, steps 2 and 3).
3.
Fix the base to the wall between 1.8 and 3.0 m (5.9 and
9.8 ft.) from the floor. For flat mounting use a minimum of
two screws (DIN 7998) in positions A. For corner-mounting
use screws in positions B or C (Figure 3). To install a pry-
off tamper, use position A or C.
J4
J3
J4
J3
J4
J3
CP
Normal
4.7 k
A
larm
9.4
kΩ
Tamper
Short
0