8870
or SaveProg .
Programming phase:
1) Remove the interphone cover.
2) Press and hold the RESET pushbutton on the interphone.
3) Press and hold the tab on the lock release pushbutton and the self start/
auto-activation (on top right hand side) pushbutton (Attiv-top on the right
hand side) together with the RESET pushbutton.
4) Release the RESET pushbutton, keeping the other two pushbuttons
pressed.
5) After 2 seconds the interphone emits a high tone and communication is
enabled with the panel.
6) Release the tab on the lock release pushbutton and the self start pushbut-
ton.
7) On pushbutton entrance panels, press the call button for the "master" in-
terphone, while on alphanumeric keypads, enter the call code of the "mas-
ter" interphone and press pushbutton "
Pushbutton programming
The interphone is supplied with a pushbutton, for the functions auxiliary ser-
vice "stair light", which activates the 1st relay of the 1st actuator (type 69RH).
To change the operating mode of push-button, use programmer type 950C
or SaveProg, with the exception of the programming push-button as inter-
communicating or for the self-start service associated with a specific panel.
If a pushbutton is programmed for a specific function, the interphone emits a
"Click" when pressed; otherwise it does not emit any signal.
Intercommunicating call pushbutton programming
Programming phase:
1) Raise the handset of the interphone/video interphone to call (when
using series 8870, Giotto, Petrarca). With other versions of series
6600 (without handset) press and keep pressed the talk/listen
push-button
.
2) Remove the cover of the interphone to be programmed.
3) Press and hold the RESET push-button on the audio door entry unit to
program.
4) Press and hold the stair light pushbutton to make the intercommunicating
call together with the RESET pushbutton.
5) Release the RESET pushbutton, keeping the stair light pushbutton
pressed.
6) After 2 seconds the interphone emits a high tone, while the other inter-
phone emits a 3-tone ascending scale.
7) Release the stair light pushbutton.
8) On the interphone called (with the 3-tone ring), press one of the pro-
grammed pushbuttons (such as lock, F1, F2 or actuator).
9) A high tone confirms the end of the procedure.
Programming the self-start pushbutton to a specific panel.
Programming phase:
1) Remove the interphone cover.
2) Press and hold the RESET pushbutton on the interphone.
3) Press and hold the stair light pushbutton together with the RESET push-
button.
4) Release the RESET pushbutton, keeping the stair light pushbutton
pressed.
5) After 2 seconds the interphone emits a high tone.
6) Release the self start pushbutton.
7) On pushbutton entrance panels, press the call button for the interphone,
while on alphanumeric keypads, enter the call code and press pushbutton
"
".
8) A high tone confirms the end of the procedure.
Restoring default values of pushbutton (for stair light (P2).
Programming phase:
1) Remove the interphone cover.
2) Press and hold the RESET pushbutton on the interphone.
3) Press and hold the relative stair light pushbutton together with the RESET
pushbutton.
4) Release the RESET pushbutton, keeping stair light push-button pressed.
5) After 2 seconds the interphone emits a high tone.
6) Release the stair light pushbutton and then press again.
EN
".
Deleting all settings.
Programming phase:
1) Remove the interphone cover.
2) Press and hold the RESET pushbutton on the interphone.
3) Press and hold the self start pushbutton (ATTIV) together with the RESET
ATTIV. pushbutton.
4) Release the RESET pushbutton, keeping the self-start pushbutton
pressed.
5) After 2 seconds the interphone emits a continuous tone for two seconds.
6) Release the self-start pushbutton.
7) During the continuous tone, press the tab on the lock release pushbutton.
If the deletion procedure is successful, when the lock release tab is pressed
once more the interphone emits a triple "Beep".
Operation
Calls from an entrance panel, intercommunicating calls and door calls are
differentiated by means of different tones.
Door calls.
Calls from entrance panels do not follow the pressed pushbutton but are
generated inside the interphone. The call interval is 1 second of ringtone and
2 seconds of pause repeated twice (default value set on panel). To answer,
raise the handset. If the handset is already raised during the call, replace
and raise it again. The call answer time (30 s) and the conversation time (2
minutes by default) are set in the panel parameters. When the conversation
time has elapsed, the user can continue without replacing the handset if a
new call is made within 10 seconds from the same panel.
Intercommunicating call.
Lift the handset and press the intercommunicating button for the interphone/
monitor to be called. On the handset of the interphone called a call tone will
ring (if the call is enabled) or an engaged tone (if not enabled). On the called
interphone the ringtone starts sequentially at intervals of 1 second ringing and
4 seconds pause. The maximum duration of the call is 30 seconds (6 cycles).
To answer the call, simply raise the handset; the maximum duration of the
conversation is 5 minutes. When the conversation time has elapsed, the user
can continue without replacing the handset if a new call is made within 10
seconds. Calls from the panel have priority over intercommunicating calls.

Lock Button

The lock button of each device works in the following manner.
- Device with handset at rest
it has spoken or from which it has been called.
- Device with handset raised but not engaged in a conversation
switchboard if the Switchboard flag is YES. Otherwise it goes back to the
first case.
- Device with handset raised and engaged in an internal conversation
as in the first case.
- Device with handset raised and engaged in an external conversation or
called from entrance panel lock
with or from which it has been called.
In practice a lock is always activated except when the handset is raised and
you immediately press the lock button. This can also be taken to the stand-
ard case if the system has no porter switchboard and the Switchboard flag
is set on NO.