Frequent questions
1.
Can several regulators MPPT be installed in the same installation
sharing the same battery bank?
Yes, with no problems.
2. Can several turbines be connected to the same regulator?
No, this is not possible, as the regulator must measure all the
parameters of the turbine, and if there are more than one, it would
not function correctly.
3. Can several wind turbines be installed with a single anemometer?
No. To do this you can use the Wind Sensor Cluster, which admits up
to 10 regulators or interfaces .
4. Is polarity important in the connection of the turbine wires?
No, it does not matter..
5. Is polarity important in the battery wires?
Yes, very important. It is essential to place the polarity correctly, as
otherwise the unit would be damaged.
6. Must there be some protection between the turbine and the
regulator?
No protection is necessary. What you can do is put in a switch that
short-circuits the three phases of the turbine in order to block it
completely..