Solution to problems

Problem
The wind turbine does not
rotate
The screen is black and no
values are shown
Possible cause
Emergency stop button is
activated
Stop button on the screen
was pressed
Battery charged
High wind
Battery voltage measured is
different from programmed
voltage
High temperature
The anemometer is
configured and there are
revolutions but there is no
wind measurement
There is a timer that turns
off the screen so that the
unit consumes less time.
The time can be adjusted
Solution
Disactivate the button
by turning it slightly
to the left
On the screen click on
the button again to
deactivate it
It is necessary to wait
until the battery
voltage drops to the
established level
It is necessary to wait
until the wind drops
to below the
programmed level
Check the
configuration of the
battery; the voltage
measured should
coincide with the
programmed voltage
Check to see if the
temperature is high. If
it is, it is necessary to
wait until it cools
Check the connection
of the anemometer
because RPMs are
being detected but
there is no wind
reading
Press the screen
again. If you want to
change the time,
contact your
distributor