The installation, transformation and repair of appliances for professional kitchens as well as removal due to
malfunction, and the supply of gas, may be made only by means of a maintenance contract stipulated with an authorised
sales office and in observance of technical regulations.
The appliance can be installed by itself or in a series side by side with appliances produced by us. There must be a
minimum distance of at least 10 cm between the appliance and the sides of the nearby cabinets made of inflammable
material. Take suitable measures to guarantee thermal insulation of the inflammable sides, such as, for example, the
installation of protection against radiaton. The appliances must be installed in a suitable manner, observing the safety
standards. The small feet are adjustable to level the appliance.
The gas must be connected using steel or copper pipes, or with flexible steel pipes, in accordance with the laws of the
country where the appliance is installed.
Each appliance must be furnished with an easy-closure cutoff cock for the gas.
After installation, a check must be made for possible gas leaks from the fittings; do not use a flame for this purpose, but
non-corrosive substances, for example a solution of soapy water or a spray which makes any leaks evident.
All of our appliances undergo rigorous controls: the type of gas, the functioning pressure and the category to which it
belongs are indicated on the data plate.
The appliance is supplied without the connection cable. To install the power supply cable, proceed as follows:
If this cable must be replaced, proceed as follows:
-
disconnect it from the main
-
Remove the back panel (for models CF4-8ET CFC4-8ET)
-
Remove the middle dividing panel, which is located under the basins (for models CF4-8G CFC4-8GEM)
-
Disconnect the cable from the mains terminal board
-
Loosen the cable clamp and remove the cable
-
Run the new cable through the cable clamp, connect the conductors to the correct terminals on the terminal board
and fasten them securely.
-
The earthing wire must be longer than the other conductors so that if the cable clamp breaks, it will be the last to be
disconnected.
N.B.: The mains cable must correspond to the following: it must at least have the specifications of a type
FG4G4/2 T.180°C cable, and a cross-section which is appropriate for the power of the appliance (see Technical
Specifications Table page 12).
The appliance must be connected to an equipotential system. The connection screw is positioned on the rear part of the
appliance and is distinguished by the symbol
Warning:
The manufacturer is not responsible and does not give
any damage due to installations that are inadequate and that are not in accordance with the instructions.
Check if the thermal power is correct:
•
The thermal power is indicated on the data plate of the appliance;
•
First check whether the appliance is set up for the type of gas supplied, then ensure that the information on the data
plate corresponds to the gas to be used. When adapting to another type of gas, check that the characteristics of that
gas conform to the specifications given in this instruction manual.
The pressure is measured using a pressure gauge (smallest unit of measure 0.1 mbar) which is inserted in the
appropriate outlet (see figure 1, pos. 10). Remove the sealing screw and insert the tube of the pressure gauge. After
measurement, replace the screw, tighten it and check if it is watertight. .
Connection for liquid gas G30/G31
The connection pressure for liquid gas is 28 mbar for butane, 37 mbar for propane.
Check the data plate, measure the pressure and see whether the description of the nozzle installed corresponds with the
one given by the manufacturer.
Connection with natural gas (methane) H G20
The connection pressure of natural gas is 20 mbar.
Check the data plate, measure the pressure and see whether the description of the nozzle installed corresponds with the
one supplied by the manufacturer.
GB
IT
GAS CONNECTION PIPE
CONNECTION TO THE MAINS
EQUIPOTENTIAL
CHECKING THE THERMAL POWER
46
IE
CH
compensation under guarantee for