Pin 13 - Switch Input #1
Pin 14 - Switch Input #2
Pin 15 - Switch Input #3
29 Pin Male Mixed AWG Connector
Pin
Type
Potential Function
Number
Pin 16 - Switch Input #4
1
Power Input
+ Battery
(Vehicle)
Pin 17 - Switch Input #5
2
- Battery
3
Power Input
+ Battery
(Aux. Battery Box)
Pin 18 - Switch Input #6
4
- Battery
5
H-Bridge
+ (Open)
Pin 19 - Switch Input #7
Axis #5
6
- (Close)
7
Logic Output #1
Panel LED (2A Max)
Pin 20 - Switch Input #8
8
Logic Output #2
Discharge ON (2A Max)
9
Logic Output #3
CAFS On (2A Max)
Pin 21 - Switch Input #9
10
Bi-stable Relay
Common
Contact Output
11
N.O. (1A Max) (STOWED)
Pin 22 - Aux. Power (1 Amp)
(Form C)
12
N.C. (1A Max) (DEPLOYED)
Pin 23
13
Switch Input # 1
Enable Input
14
Switch Input # 2
(+v) Right/Left (-v)
Pin 24
15
Switch Input # 3
(+v) Up/Down (-v)
16
Switch Input # 4
(+v) Stream/Fog (-v)
Pin 25 - Common (Ground)
17
Switch Input # 5
(+v) Discharge
18
Switch Input # 6
Unused
Pin 26
19
Switch Input # 7
Oscillate Set (+v) Pause/Resume (-v)
20
Switch Input # 8
(+v) Deploy/Stow (-v)
Pin 27
21
Switch Input # 9
(+v) CAFS Dry/CAFS Wet (-v)
22
Battery + Out
Peripheral Power (1A Max)
Pin 28
23
Data +
To external J1939
Vehicle CAN bus
Pin 29
24
Data -
25
Battery – Out
Peripheral Power (Common Ground)
26
Data +
NOT USED
27
Data -
28
Data +
NOT USED
29
Data -
D.
BATTERY ATTACHMENT
The battery connections should be the last connection made. Use the butt splice connections on the J1 harness and
connect the battery cable (#10-2 or #12-2 depending on length).
NOTE: To supply enough current to operate the monitor properly, adequate wire size is critical.
OPERATING INSTRUCTIONS
A.
CONTROLLER OPERATION
The controller is used to control the monitor and nozzle.
1. To deploy the monitor for use: Push and hold the deploy toggle switch up for 2 seconds and release.
2. To stow the monitor after use: Push and hold the stow toggle switch down for 2 seconds and release.
Note: Some controllers are not equipped with a stow/deploy switch. If another controller has been used to
stow the monitor, another function such as raise/lower or left/right can be used to remove the monitor from
stow. Just hold the selected switch for 2 seconds.
3. To change the horizontal monitor position toward the right or left: Press the proper toggle switch toward
"RIGHT" or "LEFT" respectively, as labeled on the controller, until the desired position is reached.
4. To change the vertical monitor nozzle position upward or downward: Press the proper toggle switch toward
"RAISE" or "LOWER" respectively, as labeled on the controller, until the desired position is reached.
5. To change the nozzle pattern toward the straight stream or fog position: Press the proper toggle switch toward
"STRAIGHT" or "FOG" respectively, as labeled on the controller, until the desired nozzle position is reached.
6. Joystick with trigger for valve: If there is an Akron Brass valve connected to the system, press and hold the
joystick trigger to open the valve and release the trigger to close the valve. Alternately, to maintain the valve
open position, double-click the trigger and the valve will stay open until the trigger is momentarily
pressed again.
B.
EMERGENCY STOP (Operator Override) DURING DEPLOY OR STOW
If it is necessary to immediately stop the Severe Duty monitor during the deploy or stow sequence, activate any
switch on the control panel and the unit will stop moving. To continue operation after an emergency stop,
operate any switch or press the Stow or Deploy switch to continue the sequence.
Comments
Main Battery
Auxiliary Battery
(Optional)
Electric Valve
Current Sourcing
(2A Max)
nable Output to
Warning Light
Circuit or other
- Data + Vehicle
Safety Interlock
- Data - Can
- Data + Proprietary
- Data - Can
Communications
- Data + VMUX-COM A
to
Vehicle bus and/or
- Data - Network-COM B
Smart peripherals
NOTE:
THIS DETAIL IS FOR REFERENCE ONLY AND SHOULD NOT
BE USED TO CREATE THE GRAPHICS.
USE THE ADOBE ILLUSTRATOR FILE TO PRODUCE
THE ACTUAL SILKSCREEN GRAPHICS.
AWG
12
12
12
12
16
16
16
16
28
16
16
27
16
15
16
26
16
14
16
16
25
16
16
20
16
20
16
16
16
16
16
16
16
16
16
Page 7
READ OPERATING
5
6
17
29
18
1
16
7
2
4
3
13
10
23
24
11
12
12/24 V
19
20
8
21
9
22
AKRON B
WOOS
www.akr