3.1.2
Distance from the water
G
Electrical components of the filter system operate with a rated voltage of U
supplied via an external transformer connected to the mains.
• Filter system with UVC clarifier fitted:
– The filter system and transformer must be located at a distance of at least 2 m from the water.
• Filter system without UVC clarifier fitted:
– The filter system can be installed directly next to the water. The transformer must be located at a dis-
tance of at least 2 m from the water.
3.1.3
Protective measures for swimming ponds
Adhere to the following conditions for dry installation:
H, I
• Only pumps with a voltage of ≤12 V permit immersion set-up.
• Pumps with a voltage of ≥12 V permit dry set-up, provided the required safety distance from the pond is
observed.
3.2
Connecting the inlet
The filter system has two inlets with stepped hose adapters.
• For connecting a filter pump
• For connecting a UVC clarifier (→ Connecting a UVC clarifier)
• If an inlet is not used, fit a closed stepped hose adapter.
– The stepped hose adapters are delivered closed.
Prerequisite:
• The container is open. (→ Opening the container)
• The screen holder is hinged up. (→ Hinging the screen holder up/down)
How to proceed:
J
1. Shorten the stepped hose adapter to the diameter of the hose used.
– This reduces pressure losses.
2. Insert the stepped hose adapter with flat seal into the inlet opening.
3. Screw the distributor nut with O ring onto the stepped hose adapter and hand tighten.
– BioTec ScreenMatic² 38000: Alternatively fit a 50 mm (2") hose connector.
4. Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the hose clip.
= 12 V. The supply voltage is
DC
- EN -
17