EN
NEX D/DX
5
Using NEX D/DX
WARNING!
Check that no objects which can cause sparking or fire are sucked in to the
arm.
• Avoid impacts against the hood.
• Avoid mixing dust from different processes, for example service works and
plastic grinding mixed with metal grinding.
See Figure 12. The extractor arm can easily be positioned at any point within
its working area. It can be rotated 180° when wall mounted and 360° when
ceiling mounted. For best capture the hood should be positioned as near the
fume or dust generating process as possible. The hood (on some models) is
equipped with a damper which can be adjusted with a lever.
Recommended air flow: 1700 m
Always check that the airflow is sufficient in the hood before work begins.
Insufficient airflow is depending on:
•
The fan impeller rotating in the wrong direction.
•
Hood, hose or 90°-bend are blocked.
•
Filter cartridges are blocked.
6
Spare parts
Installation, repair and maintenance work is to be carried out by qualified
personnel using only original Nederman spare parts. Contact your nearest
authorized distributor or Nederman for advice on technical service.
Ordering spare parts
When ordering spare parts always state the following:
•
Part number and control number (see the product identification plate).
•
Detail number and name of the spare part (see www.nederman.com).
•
Quantity of the parts required.
7
Recycling
The product has been designed for component materials to be recycled.
Its different material types must be handled according to relevant local
regulations. Contact the distributor or Nederman if uncertainties arise when
scrapping the product at the end of its service life.
16
Ignition risk for some dust or solvents.
/h (1000 cfm). Also check local directions.
3