Out-of-Water (Non-Submersible) Installation
Refer to Figure 3, Figure 4, and the following steps to configure the
pump for out-of-water (non-submersible) use:
1. Locate the electical connection box in a dry area at least 6-1/2
feet (2 meters) from the edge of the water.
2. Place the pump out of the water and below water level, ensuring
that water can flow into the pump. (The pump is not self-priming.)
3. Connect intake pipe (S) and discharge pipe (D) to the pump,
ensuring that the connections are watertight. NOTE: To help
prevent clogging, use a pre-filter on the intake hose.
4. Fill the intake hose and the volute with water.
5. Connect the pump to power.
6. Observe that the pump operates properly. Ensure that the
pump will not run dry; without a continuous supply of water
damage will result and void the warranty.
7. If reduced flow is required, restrict the discharge. Never restrict
the intake.
MAINTENANCE
DISCONNECT
THE
PUMP
ATTEMPTING TO SERVICE OR REMOVE ANY COMPONENT!
CAUTION: Do not let the pump freeze. This can cause cracking or
distortion that will damage the pump.
NOTE: This pump has no user-serviceable parts. The motor
housing is sealed and does not require service. Disassembly of the
motor housing will void the warranty.
NOTE: The power cord is not replaceable. If it becomes damaged,
the entire pump must be replaced. Alteration of the power cord will
void the warranty.
2
FROM
POWER
BEFORE
Min. 6.5 ft. (2m)
D
NOTE: How often the pump requires cleaning depends upon the
cleanliness of the water it pumps. When using the pump in hard
water, clean the rotor assembly and the motor housing more often.
CLEANING (FIGURE 5):
1. Disconnect the pump from power.
2. Remove the intake screen filter (1) (if in use)
a. Remove the screw (9) on the underside of the screen
b. Unsnap the clips (8) on each side of the screen from
the pump housing
3. Remove the four housing screws (7) securing the volute (2) to
the motor housing (6).
4. Remove the volute from the motor housing.
5. Remove the rotor assembly (4).
6. Clean all parts with clean water and a sponge.
7. Inspect all parts and replace any that are damaged or
excessively worn. (Refer to the Replacement Parts table.)
8. Install the o-ring (3) onto the volute (2).
9. Carefully slide the rotor assembly (4) into the motor housing (6)
ensuring that the two holes in the plate align with the two pins
on the housing.
10. Check to ensure that the rotor assembly rotates easily.
11. Using the four screws (7), attach the volute (2) to the motor
housing, ensuring that the o-ring remains in place.
12. Install the intake screen filter by snapping the clips (8) to the
pump housing and securing the bottom attachment screw (9).
13. Restore power to the pump and check for proper operation. Refer to
the Troubleshooting section if the pump is not operating properly.
FIG. 3
Filter
M
FIG. 4
S

Publicidad