Features of the railmounting plate
The possibility of reusing the Mounting Plate without breaking the model requires care
with the side finishing of the plaster on the plate, i.e., the plate should not have plaster at
the lateral border (fig. 11).
In order to take off the model, the plaster should be removed of from the retention hole
(fig. 12) and then the model should be hold while tapping the plate towards the indicated
arrows located on the lower face of it (fig. 13).
PS.: Once the model has been taken off the Mounting Plate, we can not guarantee the
returning of it in the initial position with precision, since it depends on the technical
quality of the work and the materials used (especially the plaster).
Fig. 11

MAINTENANCE AND CLEANING

• This manual only contains basic and simplified information regarding the use of the
instrument and under no circumstances it is a substitute for a proper training course.
The articulator and face-bow are products aimed at the exclusive use of qualified
dental Professionals.
• The R-010098 articulator is not interchangeable, i.e. the casts mounted on one
articulator model should not be transferred (mounted) to any other articulator.
Therefore, Mestra does not guarantee precision when casts mounted on one
articulator are transferred to another.
• Before using the articulator and face-bow, the professional should check the
instrument for possible damage, distortion of the incisal pin, face-bow's parallelism,
proper centricity of the incisal pin in relation to the lower frame, etc. Should any
abnormality be found, contact your distributor.
• Mestra recommends only warm water for the general cleaning of the articulator and
facebow.
• When using "godiva" or any other registration material, special care should be taken
to avoid excessive heating of the material, which might burn the patient's mouth.
Mestra urges the user to carefully follow the instructions of the registration material
manufacturer.
• Because the articulator is a precision instrument, it should be handled, transported
and stored carefully.