Electrical Requirements; Recommended Grounding Method - Thermador KBUIT4255E Instrucciones De Instalación

Refrigeradores empotrados
Ocultar thumbs Ver también para KBUIT4255E:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

If the anti-tip boards are needed, they must be attached to
the rear wall studs 80" to 90" (203 to 229 cm) above the floor.
See "Install Anti-Tip Boards" for more information.
NOTE: A clearance of ¹⁄₂" (1.3 cm) must be maintained above
the top grille in order for the top grille to be removed.
A grounded 3 prong electrical outlet should be placed within
4" (10.2 cm) of the right side cabinets or end panel. See
"Electrical Requirements" for additional information.
The water shutoff should be located in the base cabinet on
either side of the refrigerator or some other easily accessible
area. If the water shutoff valve is not in the cabinets, the
plumbing for the water line can come through the floor or the
back wall. See "Water Supply Requirements" for more
information.
80" - 90"
(203-229 cm)
¹⁄₂
83
" (212.1 cm) min.
³⁄₄
84
" (215 cm) max.
to bottom of solid soffit
Width
(see chart following)
6"
(2.54 cm)
(15.2 cm)
24"
(60.96 cm) min.
Model
Width A (as shown above)
42
41¹⁄₂" (105.4 cm) to 41³⁄₄" (106.1 cm)
48
47¹⁄₂" (120.7 cm) to 47³⁄₄" (121.3 cm)
¹⁄₂
"
(1.3 cm)
4"
(10.2 cm)
77"
(196 cm)
A
6"
(15.2 cm)
1"
6"
(15.2 cm)
E l e c t r i c a l R eq u i re m e n t s
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Before you move your refrigerator into its final location, it is
important to make sure you have the proper electrical connection.

Recommended Grounding Method

A 115 Volt, 60 Hz., AC only, 15- or 20-amp fused, grounded
electrical supply is required. It is recommended that a separate
circuit serving only your refrigerator be provided. Use an outlet
that cannot be turned off by a switch. Do not use an
extension cord.
IMPORTANT: If this product is connected to a GFCI (Ground
Fault Circuit Interrupter) protected outlet, nuisance tripping of the
power supply may occur, resulting in loss of cooling. Food quality
and flavor may be affected. If nuisance tripping has occurred,
and if the condition of the food appears poor, dispose of it.
NOTE: Before performing any type of installation, cleaning, or
removing a light bulb, remove the top grille and turn the master
power switch to OFF or disconnect power at the circuit breaker
box.
When you are finished, turn ON the master power switch or
reconnect power at the circuit breaker box. Then reset the control
to the desired setting.
15

Publicidad

Tabla de contenido
loading

Tabla de contenido