Disinfection
• The materials used for the construction of our products meet the standards for use with potable water; the manufacturing
processes are also geared to preserving these criteria. However, the process of production, distribution, assembly and
installation, may create conditions of bacterial proliferation, which may lead to odour problems and water contamination;
• it is therefore strongly recommended to sanitize the products;
• maximum cleanliness is recommended during the assembly and installation;
• for disinfection, use sodium or calcium hypochlorite and perform a manual regeneration.
3 .
Description
3.1.
Technical specifications
3.1.1. General
Softener type
Foleo .................................................................10L .......................15L .......................20L .......................30L
Design specifications/ratings
Softener cabinet ...............................................ABS
Tank body..........................................................Dowex
Valve body .........................................................Glass-filled Noryl
Rubber components .........................................Compounded for cold water - NSF listed material
Valve material certification ..............................WQA Gold Seal Certified to ORD 0902, NSF/ANSI 44, CE, ACS
Volume of resin.................................................10 L ......................15 L ......................20 L ......................28 L
Approximative shipping weight ........................12 kg.....................20 kg.....................30 kg ....................35 kg
Salt storage.......................................................15 kg.....................15 kg.....................25 kg ....................25 kg
Operating pressure...........................................1.4 - 8.6 bar
Hydrostatic test pressure.................................20 bar
Water temperature ...........................................1 - 43°C
Ambient temperature .......................................0 - 52°C
3.1.2. Performance flow rate characteristics
Note
Flow rates are indicative data. Maximum flow rate to produce in order to respect the required service
velocity for an optimal ion exchange upon resin manufacturers recommendation, regardless of the
inlet pressure.
Nominal (residual hardness 0°f) ......................0.60 m
Nominal (residual hardness 5-10°f).................0.72 m
Peak (residual hardness 5-10°f) ......................1.00 m
Ref. MKT-UG-038 / D - 15.11.2019
Drain
Outlet
Inlet
Overflow
®
HCRS-s resin
®
- NSF listed material
3
3
/h .............0.90 m
/h .............1.20 m
3
3
/h .............1.08 m
/h .............1.44 m
3
3
/h .............1.50 m
/h .............2.00 m
User Guide Foleo
3
3
/h .............1.68 m
/h
3
3
/h .............2.02 m
/h
3
3
/h .............2.80 m
/h
7 / 116