Franklin Electric Little Giant 8E-CIA-RFS Manual De Instrucciones
Franklin Electric Little Giant 8E-CIA-RFS Manual De Instrucciones

Franklin Electric Little Giant 8E-CIA-RFS Manual De Instrucciones

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Franklin Electric Co., Inc.
P. O. Box 12010
Oklahoma City, OK 73157-2010
405.947.2511 • Fax: 405.947.8720
www.LittleGiantPump.com
CustomerService-WTS@fele.com
INTRODUCTION
EN
This instruction sheet provides you with the information required
to safely own and operate your product. Retain these instructions
for future reference.
The product you have purchased is of the highest quality work-
manship and material, and has been engineered to give you
long and reliable service. This product has been carefully tested,
inspected, and packaged to ensure safe delivery and operation.
Please examine your item(s) carefully to ensure that no damage
occurred during shipment. If damage has occurred, please con-
tact the place of purchase. They will assist you in replacement or
repair, if required.
READ
THESE
INSTRUCTIONS
ATTEMPTING
TO
INSTALL,
YOUR PRODUCT. KNOW THE PRODUCT'S APPLICATION,
LIMITATIONS,
AND
POTENTIAL
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION.
FAILURE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY
AND/OR PROPERTY DAMAGE!
DESCRIPTION
Little Giant submersible effluent pumps are recommended for
use in basins or lift stations and are suitable for pumping sew-
age, effluent, wastewater and other non-explosive, non-corrosive
liquids with up to 3/4" spherical solids.
Automatic operation can be achieved with the use of the Remote
Float Switch (RFS). Other accessories such as basins, check
valves, and covers are also available.
Figure 1
8E-CIA-RFS
8E-CIM
9E-CIA-RFS
9E-CIM
Submersible Effluent Pump
Pompe Pour Effluent Submersible
Bomba Efluente Sumergible
CAREFULLY
BEFORE
OPERATE,
OR
SERVICE
HAZARDS.
PROTECT
TO
COMPLY
WITH
THESE
8E-CIA SERIES
SPECIFICATIONS
Discharge Size:
1-1/2" NPT vertical
Intake Size:
3/4" screened opening
Pump Housing:
Cast iron
Volute:
Cast iron
Screen:
ABS
Impeller:
Vortex design, with pressure relief vanes
Motor:
Single phase induction, 1750 RPM, with auto-
matic reset thermal overload protection
Hardware:
300 Series stainless steel
Thrust Bearing:
Double shielded ball
Radial Bearing:
Sleeve — permanent lubrication
Pump Shaft Seal: Mechanical, spring loaded, stationary carbon
with Nitrile boot and rotating ceramic seat
Power Cord:
16 AWG 3-conductor, copper, stranded
Cooling:
The motor housing contains oil to cool the
motor and to lubricate bearings and seals.
These pumps are capable of operating with the
motor housing partially exposed for extended
periods of time, providing sufficient motor cool-
ing and bearing lubrication. However, for the
best cooling and longest motor life, the liquid
level being pumped should normally be
above the top of the cast iron motor housing.
SAFETY GUIDELINES
WARNING: RISK OF ELECTRIC SHOCK. This pump is supplied
with a grounding conductor and grounding-type attachment plug.
To reduce the risk of electric shock, be certain that it is connected
only to a properly grounded, grounding-type receptacle.
Your 115V pump is equipped with a 3-prong electrical plug. The
third prong is to ground the pump to prevent possible electrical shock
hazard. Do not remove the third prong from the plug. A separate
branch circuit is recommended. Do not use an extension cord.
9E-CIA SERIES
1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Franklin Electric Little Giant 8E-CIA-RFS

  • Página 1 8E-CIA-RFS SPECIFICATIONS 8E-CIM Discharge Size: 1-1/2” NPT vertical Intake Size: 3/4” screened opening 9E-CIA-RFS Franklin Electric Co., Inc. Pump Housing: Cast iron P. O. Box 12010 9E-CIM Oklahoma City, OK 73157-2010 Volute: Cast iron Submersible Effluent Pump 405.947.2511 • Fax: 405.947.8720 www.LittleGiantPump.com...
  • Página 2 Figure 2 - Typical Installation/ Separate protected and grounded service outlet 4 ft. from floor min. • Prise de courant de mise à la terre à protection séparée à une distance minimale de 4 pi du sol • Tomacorrientes Installation Type/Instalacion Tipica de servicio conectado a tierra y protegido separado por lo menos a 4 pies del suelo.
  • Página 3 a. Remove the plug from the receptacle prior to touching, MANUAL SEWAGE EJECTOR PUMPS: servicing or repairing the pump. The power cord for these pumps can be plugged directly into a properly grounded receptacle with voltage consistent with pump b. To minimize possible fatal electrical shock hazard, use nameplate for continuous pump operation.
  • Página 4 REMOTE FLOAT SWITCH INSTALLATION Attaches: Acier inoxydable, série 300 1. The float switch consists of three parts: switch, cord clamp, Palier à Butée: Billes clamp screw. NOTE: If screw is lost, use a #10-16 x 1/2” long Palier Radial: Manchon — lubrification permanente tapping screw.
  • Página 5: Directives D'ENtretien

    3. Durant le fonctionnement normal du système, la pompe à FONCTIONNEMENT puisard est immergée, donc invisible. De plus, pendant les orages, VÉRIFICATION DU BON FONCTIONNEMENT DE LA POMPE il pourrait y avoir de l’eau autour de la pompe. C’est pourquoi POMPE À...
  • Página 6: Introducción

    La pompe devrait être branchée à un circuit indépendant. Aucun CUÁLES SON LAS APLICACIONES, LIMITACIONES Y PELIGROS autre appareil ne devrait être branché à ce circuit, et les fusibles POTENCIALES DE LA UNIDAD. PROTEJA A TERCEROS Y et disjoncteurs devraient être de capacité adéquate. Consulter le PROTÉJASE A USTED MISMO SIGUIENDO TODA LA tableau ci-dessous.
  • Página 7: Instalacion

    Cuando la bomba se encuentre en un dique seco, etc., no toque inadecuado o de fugas en la bomba a causa de fallos en la el motor, los tubos ni el agua, mientras no se encuentre desco- alimentacion electrica, bloqueo de la linea de la descarga, o nectada o apagada.
  • Página 8: Limpieza Del Rotor Y El Difusor

    siguiendo estos pasos, consulte al distribuidor de la bomba o Las bombas de la serie RFS están equipadas con un control de lleve la bomba a un centro de servicio autorizado de Little Giant. nivel activado por un interruptor remoto de flotador. Este control de nivel está...
  • Página 9 Figure 4 ITEM PART NO. DESCRIPTION 114114 Handle 109150 Base, screen 109151 Plate, base 909024 Screw/washer, #10-24 X 1.46 901424 Screw/washer, #8-32 X 1/2" 927027 Clamp, cord 950314 Switch, remote float 950315 Switch, remote float 950307 Switch, remote float...
  • Página 10 TROUBLESHOOTING INFORMATION • INFORMATION SUR LA RELÈVE DES DÉRANGEMENTS • INFORMACION DE INVESTIGACION DE AVERIAS PROBLEM • FONCTIONNEMENT DÉFECTEUX PROBABLE CAUSES • CAUSES PROBABLES • PROBLEMA • CAUSAS PROBABLES CORRECTIVE ACTIONS • SOLUTIONS • SOLUCION Pump not plugged in. • La pompe n’est pas branchée. • La bomba Pump does not turn on.
  • Página 11: Garantie Limitée

    à sa sortie de l’usine. Pour la durée et selon les conditions men- WARRANTY. tionnées dans les présentes, LITTLE GIANT, filiale de Franklin Electric Company, Inc., réparera ou remplacera au profit de l’acheteur ou de l’utilisateur initial WARRANTY PERIOD toute partie du produit LITTLE GIANT qui, à...
  • Página 12: Garantia Limitada

    ..... . .1-888-572-9933 Para la ayuda técnica, por favor póngase en contacto ..1-888-956-0000 www.LittleGiantPump.com CustomerService-WTS@fele.com Form 993629 - 09/29/2009 © 2009 Franklin Electric Co., Inc. Little Giant® is a registered trademark of Franklin Electric Co., Inc.

Este manual también es adecuado para:

Little giant 8e-cimLittle giant 9e-cia-rfsLittle giant 9e-cim

Tabla de contenido