Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Franklin Electric Co., Inc.
Oklahoma City, OK 73157-2010
www.LittleGiantPump.com
E N G L I S H
customerservice@lgpc.com
ENGLISH
EN
This instruction sheet provides you with the information required
to safely own and operate your product. Retain these instructions
for future reference.
The product you have purchased is of the highest quality
workmanship and material, and has been engineered to give you
long and reliable service. This product has been carefully tested,
inspected, and packaged to ensure safe delivery and operation.
Please examine your item(s) carefully to ensure that no damage
occurred during shipment. If damage has occurred, please
contact the place of purchase. They will assist you in replacement
or repair, if required.
READ
THESE
INSTRUCTIONS
ATTEMPTING
TO
INSTALL,
YOUR PRODUCT. KNOW THE PRODUCT'S APPLICATION,
LIMITATIONS,
AND
POTENTIAL
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION.
FAILURE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY
AND/OR PROPERTY DAMAGE!
DESCRIPTION
This is a submersible effluent pump for use in basins or lift
stations, and is suitable for pumping sewage, effluent, wastewater,
and other non-explosive, non-corrosive liquids with up to 1/2"
spherical solids.
SAFETY GUIDELINES
1. Make certain pump is disconnected from power source before
attempting to service or remove any component.
2. Do not use to pump flammable or explosive fluids such as
gasoline, fuel oil, kerosene, etc. DO NOT use in explosive
atmospheres or hazardous locations as classified by NEC,
ANSI/NFPAT. Pump should be used with liquids compatible
with pump component materials.
3. Do not handle the pump with wet hands or when standing on
a wet or damp surface or in water.
4. Do not pull the pump out of the water by the power cord when
the pump is operating or connected to power source.
5. This pump is supplied with a grounding conductor and/or
grounding type attachment plug. To reduce the risk of electrical
shock, be certain that it is connected to a properly grounded
grounding type receptacle.
6. The National Electric Code requires a ground fault circuit
interrupter (GFCI) be installed in the branch circuit supplying
fountain equipment, pools, etc.
7. In any installation where property damage and/or personal
injury might result from an inoperative or leaking pump due to
power outages, discharge line blockage, or any other reason,
a backup system(s) and/or alarm should be used.
8. Support pump and piping when assembling and when installed.
Failure to do so may cause piping to break, pump to fail,
motor bearing failures, etc.
10EN-CIA-SFS
10EN-CIA-RF
10EN-CIM
10EN-CBM
10EN-CBA
CAREFULLY
BEFORE
OPERATE,
OR
SERVICE
HAZARDS.
PROTECT
TO
COMPLY
WITH
THESE
Figure 1 - Typical insTallaTion • insTallaTion Type •
INSTALACION TIPICA (10EN-CIA-SFS SHOWN)
9. This pump's motor housing is filled with a dielectric oil for
motor heat transfer and lifetime lubrication of the bearings.
This oil is non-toxic to aquatic life. However, suffocation can
occur if oil is left on the water surface. If oil escapes the motor
housing it can be removed from the surface quickly by placing
newspapers on the water surface to soak up the oil.
10. The pump motor is equipped with an automatic resetting thermal
protector and may restart unexpectedly. Protector tripping is
an indication of motor overloading as a result of excessively high
or low voltage, inadequate wiring, incorrect motor connections,
or a defective motor or pump.
ELECTRICAL CONNECTIONS
1. Check the pump label for proper voltage required. Do not
connect to voltage other than that shown.
2. If pump is supplied with a 3-prong electrical plug, the third
prong is to ground the pump to prevent possible electrical
shock hazard. DO NOT REMOVE the third prong from the
plug. A separate branch circuit is recommended.
Do not use an extension cord. Do not cut plug from the cord.
If the plug is cut or the cord is shortened, then this action will
void the warranty.
3. If the cord is equipped with stripped lead wires, such as on
230V models, be sure that the lead wires are connected to a
power source correctly. The green/yellow wire is the ground.
The blue (or white) and brown (or black) are live.
1

Publicidad

loading

Resumen de contenidos para Franklin Electric Little Giant 10EN-CIA-SFS

  • Página 1 Figure 1 - Typical insTallaTion • insTallaTion Type • 10EN-CIA-SFS INSTALACION TIPICA (10EN-CIA-SFS SHOWN) 10EN-CIA-RF Franklin Electric Co., Inc. 10EN-CIM Oklahoma City, OK 73157-2010 www.LittleGiantPump.com 10EN-CBM E N G L I S H customerservice@lgpc.com 10EN-CBA ENGLISH This instruction sheet provides you with the information required to safely own and operate your product.
  • Página 2 4. Check local electrical and building codes before installation. 5. Be sure gate valve in discharge line is open. The installation must be in accordance with their regulations 6. Allow pump to operate through several on/off cycles. as well as the most recent National Electrical Code (NEC). CIM SERIES EFFLUENT PUMPS 5.
  • Página 3: Directives De Sécurité

    DESCRIPTION 2. Si la pompe est équipée d’une fiche d’aiimentation électrique à trois broches, la troisième est destinée à raccorder la pompe Vous avez acheté une pompe pour effluent submersible pouvant à la terre pour éliminer les risques d’électrocution. NE PAS être utilisée dans des bassins ou dans des stations de pompage ENLEVER cette troisième broche du cordon d’alimentation.
  • Página 4: Vérification Du Fonctionnement De La Pompe

    6. Ne laissez pas l’appareil fonctionner à sec (sans liquide). Il est 5. Veillez à ce que la turbine tourne librement une fois le conçu pour se refroidir en pompant un liquide. Vous pouvez nettoyage terminé. endommager le joint et le moteur peut tomber en panne si 6.
  • Página 5: Conexiones Electricas

    5. Esta bomba se suministra con un conductor a tierra y/o un 6. La bomba debe estar conectada o cableada a su propio circuito enchufe de conexion de tipo de conexion a tierra. Para reducir sin ninguna otra salida o equipo en la línea del circuito. Los fusibles y el disyuntor deben ser de capacidad amplia en el el riesgo de descarga electrica asegurese de conectar la circuito eléctrico.
  • Página 6 2. Esta unidad se encuentra lubricada permanentemente. No se 5. Asegúrese de que la válvula de compuerta en la línea de requiere lubricación. Jamás, en ningún caso, abra la parte de descarga esté abierta. la unidad que está sellada o retire los tornillos de la caja. 6.
  • Página 7 Table 1 - Replacement Parts Figure 2 MODEL (CATALOG NO.) PART NO. DESCRIPTION 106398 Cover, 10' cord, automatic 106406 Cover, 20' cord, automatic 106339 Cover, 10' cord, manual Cover, 10' cord, automatic, 106414 230V plug Cover, 20' cord, automatic, 106404 230V plug 106340 Cover, 20' cord, manual Cover, 10' cord, manual, 230V...
  • Página 8: Causas Probables

    TrouBlesHooTing inForMaTion • inForMaTion sur la relÈVe Des DÉrangeMenTs • inForMacion De inVesTigacion De aVerias proBleM • FoncTionneMenT proBaBle causes • causes proBaBles correcTiVe acTion • soluTions DÉFecTeuX • proBleMa • causas proBaBles • solucion Pump not plugged in. • La pompe n’est pas branchée. • La bomba Plug in pump.
  • Página 9 DEFECTIVE PRODUCT. 9. Products connected to voltage other than indicated on Franklin Electric Company, Inc. and its subsidiaries (hereafter nameplate. “the Company”) warrants that the products accompanied by this 10. Products where the pump was exposed to any of the following:...
  • Página 10 UN PRODUIT DÉFECTUEUX. services, ou toute autre condition hors du contrôle de la Société. Franklin Electric Company, Inc et ses filiales (ci-après « la Société 7. N'importe quel produit qui a été utilisé à des fins autres que ») garantit que les produits accompagnés de cette garantie sont celles pour lesquelles il a été...
  • Página 11: Esta Garantía No Aplica A Ninguno De Los Siguientes Casos

    5. El uso de piezas de repuesto que no sean vendidas por la Compañía, la adición no autorizada de productos que no sean Franklin Electric Company, Inc y sus subsidiarias (en de la Compañía a productos de la Compañía, y la alteración adelante “la Compañía”) garantizan que los productos que...
  • Página 12: Descargo De Responsabilidad

    9. Productos conectados a otro voltaje distinto al indicado en la DAÑOS A O PÉRDIDA DE OTRA PROPIEDAD O EQUIPO, placa de identificación. PÉRDIDAS EQUIPO, PRESTACIÓN SERVICIO, PÉRDIDA DE GANANCIA O VENTAS, COSTO 10. Productos en los cuales la bomba fue expuesta a cualquiera DE COMPRAS O REMPLAZO DE BIENES, RECLAMOS DE de los siguientes: arena, grava, cemento, grasa, yeso, CLIENTES DEL COMPRADOR, FALLA PARA ADVERTIR...