INSTALLATION OF THE DOSATRON
A
C
©
DOSATRON INTERNATIONAL S.A.S / 49
A
Fig. 1
THE INSTALLATION ASSEMBLY SHOULD BE CARRIED OUT WITHOUT
TOOLS
The DOSATRON is delivered with :
- a mounting bracket,
- a suction hose with a strainer.
The bracket enables the DOSATRON to be mounted on a wall.
Place the DOSATRON in the bracket by spreading its arms slightly to click in
the 4 pins of the pump body (Fig. 1-A) fitting the two pins on one side of the
body (Fig. 1-A) into the corresponding holes in the bracket (Fig. 1-B).
B
Remove the plastic caps, (Fig. 1-C) which block the openings in your
DOSATRON, before connecting to the water supply line.
RECOMMENDATIONS
The DOSATRON can be connected to the water supply line by means of
20 mm interior diameter flexible pipes fixed with swivel fittings Ø 20 x 27 mm
[3/4"]. Make certain that the water flows in the direction of the arrows (water
flow) on the appliance.
Whenever possible, install the Dosatron high enough for easy reading and
adjusting of the dosing on the graduated scale in % or ratio.
Torque 20 N
i.e. 2 kg
(reminder: 1 N . m = 0.1 DaN.m)
©
DOSATRON INTERNATIONAL S.A.S / 50
.
m
.
m