1. GENERAL
This booklet briefly outlines where and how to install the
air conditioning system. Please read over the entire set of
instructions for the indoor and outdoor units and make sure all
accessory parts listed are with the system before beginning.
1-1. Tools Required for Installation (not supplied)
1.
Flathead screwdriver
2.
Phillips head screwdriver
3.
Knife or wire stripper
4.
Tape measure
5.
Carpenter's level
6.
Sabre saw or key hole saw
7.
Hacksaw
8.
Core bits
9.
Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for deburring)
1-2. Accessories Supplied with Unit
See Tables 1-1 to 1-6.
Table
Type
1-1
4-Way Cassette
1-2
4-Way Cassette 60x60
1-3
Ceiling
1-4
Low Silhouette Ducted
1-5
Slim Low Static Ducted
1-6
High Static Pressure Ducted
1-3. Type of Copper Tube and Insulation Material
If you wish to purchase these materials separately from a local
source, you will need:
1.
Deoxidized annealed copper tube for refrigerant tubing.
2.
Foamed polyethylene insulation for copper tubes as
required to precise length of tubing. Wall thickness of the
insulation should be not less than 8 mm.
3.
Use insulated copper wire for field wiring. Wire size varies
with the total length of wiring. Refer to 4. ELECTRICAL
WIRING for details.
CAUTION
Check local electrical codes and regulations before
obtaining wire. Also, check any specified instructions or
limitations.
1-4. Additional Materials Required for Installation
1.
Refrigeration (armored) tape
2.
Insulated staples or clamps for connecting wire (See your
local codes.)
3.
Putty
4.
Refrigeration tubing lubricant
5.
Clamps or saddles to secure refrigerant tubing
6.
Scale for weighing
Table 1-1 (4-Way Cassette)
Part Name
Figure
Q'ty
Remarks
Full-scale
Printed on
installation
1
container box
diagram
For suspension
Washer
8
bolts
For full-scale
Screw
4
installation diagram
For gas and liquid
(White)
Insulating tape
2
tube flare nuts
Flare insulator
1
For liquid tube
Flare insulator
1
For gas tube
Drain hose
1
Hose band
1
Packing
1
Drain insulator
1
Instruction
1
Manual
Installation
1
Instruction
Table 1-2 (4-Way Cassette 60x60)
Part Name
Figure
Q'ty
Remarks
For temporarily
Washer
8
suspending indoor
unit from ceiling
Flare
T3
2
For gas / liquid
insulation
T5
set
tube connection
For gas / liquid
Insulation tie
2
tube / flare nut
connection
For flare /
Vinyl tie
8
drain insulating
connection
Drain hose
For drain tube
T10
1
insulation
connection
Full-scale
Printed on
installation
1
container box
diagram
Washer head
For full-scale
4
screw
installation diagram
For unit & PVC
Drain hose
1
tube connection
L140
For drain hose
Hose band
2
connection
Use M10 for suspension bolts.
Field supply for suspension bolts and nuts.
7
Table 1-3 (Ceiling)
Part Name
Figure
Q'ty
Remarks
For temporarily
Special
4
suspending indoor unit
washer
from ceiling
T10
Drain
1
For drain hose joint
insulator
T5
T3
2
For gas and liquid tube
Flare insulator
sets
joints
Insulating
For gas and liquid flare
White
2
tape
joints
(heat-
resisting)
For flare and drain
Vinyl clamp
8
insulator (Field supply
for Spanish version)
Eyelet
1
For power supply inlet
Full-scale
installation
1
Printed on container box
diagram
For main unit + PVC
Drain hose
1
pipe joints
L140
For drain hose
Hose band
2
connection
Table 1-4 (Low Silhouette Ducted)
Part Name
Figure
Q'ty
Remarks
For suspending indoor
Washer
8
unit from ceiling
Flare insulator
2
For gas and liquid tubes
Insulating
For gas and liquid tubes
2
tape
flare nuts
Dain insulator
1
For drain hose joint
Hose band
1
For securing drain hose
Packing
1
For drain joint
Drain hose
1
For sealing recessed
Sealing putty
1
portion of power supply
For flare and drain
Vinyl clamp
8
insulators (Field supply)
Booster
Connector for
1
cable*
changeover to HT tap
* Booster cable is housed inside the electrical component box.
● Use M10 for suspension bolts.
● Suspension bolts and nuts are field supply.
Table 1-5 (Slim Low Static Ducted)
Part Name
Figure
Q'ty
Remarks
For suspension
Unit
8
Washer
fitting
suspension
For gas pipe /
2
liquid pipe
connection
T3
Flare
For gas pipe /
insulation
2
liquid pipe
connection
T5
Refrigerant
For gas pipe /
tubing
liquid pipe /
Insulation
2
White
flare nut
tape
(heat-resistant)
connection
For flare / drain
8
insulating
Vinyl tie
connection
For unit & PVC
1
pipe
Drain hose
connection
L140
For drain hose
Drain
2
Hose band
connection
piping
For drain pipe
Drain hose
1
connection
insulation
For power
1
supply cord
Clamper
Be sure to fix the power supply cord
with the clamper.
For high static
Others
pressure
Located on
Short
1
the back of
circuit
the electrical
connection
component box
lid.
● Use M10 for suspending bolts.
● Field supply for suspending bolts and nuts.
Table 1-6 (High Static Pressure Ducted)
Part Name
Figure
Q'ty
Remarks
For suspending indoor
Special washer
8
unit from ceiling
For gas and liquid
Flare insulator
2
tubes
For drain pipe
Drain socket
1
connection
For increasing size
of liquid tube from
Tube connector
1
ø6.35 to ø9.52 mm
(only for 73 type)
8