Install The Door Control - Craftsman 139.53910 Manual Del Propietário

Ocultar thumbs Ver también para 139.53910:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION STEP 6

Install the Door Control

Locate door control within sight of door, at a
minimum height of 5 feet (1.52 m) where small
children cannot reach, away from moving parts of
door and door hardware.
1. Strip 1/4" (6 mm) of insulation from one end of bell
wire and connect to the two terminal screws on
back of door control by color: white to 2 and
white/red to 1.
2. Fasten the Door Control Button securely with
6ABx1-1/2" screws. If installing into drywall, drill
5/32" holes and use the anchors provided.
3. Run bell wire up wall and across ceiling to motor
unit. Use insulated staples to secure wire in
several places. Do not pierce wire with a staple,
creating a short or open circuit.
4. Connect the bell wire to the terminal screws on the
motor unit panel: white to 2; white/red to 1.
5. Position the antenna wire as shown.
6. Use tacks or staples to permanently attach
entrapment warning label to wall near door control,
and manual release/safety reverse test label in a
prominent location on inside of garage door.
DO NOT connect power and operate opener
NOTE:
at this time. The troiiey will travel to the full open
position but will not return to the close position until
the sensor beam is connected and properly aligned.
WARNING
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE Installing door
control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install door control within sight of garage door, out of
reach of children at a minimum height of 5 feet
(1.52 m), and away from all moving parts of door.
• NEVER permit children to operate or play with door
control push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is
properly adjusted, and there are no obstructions to door
travel.
• ALWAYS keep garage door in sight until completely
closed. NEVER permit anyone to cross path of closing
garage door.
Outside Keylock Accessory Connections
To opener terminal screws: white to 2; white/red
to 1.
HARDWARE SHOWN ACTUAL SIZE
a
I
I I
I
Screw 6ABxl"l/2"
Lighted Door Control Button
17
Insulated
Drywail Anchors
Staples

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido