FIG A: PARTS IDENTIFICATION
FRONT
Power cord and
drain hose
storage.
Humid air inlet.
Air filter.
Drain hose
Front panel. Remove to
quick-connect.
access the pump and
coils for cleaning. See
Fig. B.
REAR
Integrated handle. Use the
red lever to lock handle
upright for use or down
for loading or storage.
Control panel.
Power cord
socket.
Drain hose quick-
connect.
Model serial
number label
Process (dehumidified)
air outlet.
Positioning a Dehumidifier
For best results, operate your dehumidifier in an
enclosed area. Close all doors and windows to maximize
the unit's water removal efficiency. Place your
dehumidifier away from obstructions, and keep it away
from anything that could obstruct airflow into and out of
the unit.
07-02300C F600
Extend handle
Release the handle by rotating red locking
lever outward, then lift handle up into place.
Rotate red lever back into locked position to
secure handle in operating position.
NOTICE: Do not use the extended handle to
lift the unit off the ground horizontally. Do not
use the extended handle as an attachment
point to strap the unit in a vehicle for
transport. These uses will place undue strain
on the handle attachment points in the
housing.
Set up drain hose
This unit automatically pumps out water on a
regular basis. This dehumidifier is equipped
with a quick-connect fitting for attachment to
the provided drain hose located in the tray on
top of the unit. Unwrap the entire hose and
place the open end in a sink, drain, bucket or
outdoors – anywhere that water can drain out
safely. If you use a bucket or other container
for water collection, check it regularly to
prevent overflows.
NOTICE: Uncoil and straighten the entire
drain hose. Do not leave any part of the hose
coiled on the unit and do not place the end of
the hose higher than 20 ft. (6 m) above the
bottom of the unit. Also check for kinks or
other obstructions that might restrict the flow
of water. A kink or blockage will cause the unit
to turn off produce an ER9 error code. See
"Error Messages," below, for more
information.
Plug in electrical cord
The dehumidifier should be plugged into a
GFCI-protected 115 volt outlet rated for at
least 15 amps. Remove the cord from the
storage tray and uncoil it. Always plug the
cord firmly into the unit first, and then plug the
other end into a suitable electrical outlet.
Startup display and normal display modes
When unit is first plugged into AC power, the
control panel display will briefly cycle through
a series of readouts. This is part of the unit's
self-diagnosis procedure and no user
intervention is required.
Turn the unit on
The control panel has a display and a touchpad with four
keys. Press the ON/OFF to turn the unit on. The unit will
now go through a compressor delay countdown (up to
60 seconds in duration) and a self-diagnostics process,
then switch to normal display mode.
2
Dri-Eaz Products, Inc.