1. SELECT BLOWER OPTION AND INSTALLATION TYPE
1.1 N
-D
I
ON
UCTED
NSTALLATION
For a non-ducted installation, the interior blower Best model iQ6, P3 or P6 must be used. (Blower sold separately.)
The non-duct kit ANKUP27M Series (sold separately) must be installed. This kit fits hood from 30-inch width up to 48-inch width. See
installation instructions included with the non-duct kit ANKUP27M Series.
1.2 D
I
UCTED
NSTALLATION
For a ducted installation, either an interior or exterior blower or in-line blower may be used with this hood. The Best UP27M Series
must be installed with blower models iQ6, P3, P6, ILB3, ILB6, ILB9, ILB11, EB6, EB9, EB12 or EB15 only.
Other blowers cannot be substituted. (Blowers sold separately.)
Plan where and how the ductwork will be installed.
NOTE: There is no horizontal exhaust on UP27M Series range hood.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 to 5, 8, 10 to 12, 15 and up of
this manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. Use metal duct tape to seal duct
joints.
NOTE: It is recommended that there be a minimum of 6" of straight duct from this hood to an elbow for 8" ducting and 12" for
10" ducting.
1.3 A
I
LL
NSTALLATIONS
The minimum hood distance above cooktop must not be less than 24''. A maximum of 36" above cooktop is highly
recommended for best capture of cooking impurities. Distances over 36" are at the installer and users discretion.
EXTERIOR BLOWER
CABINET
HOOD
COOKING SURFACE
HH0219A
MODEL EB6, EB9, EB12 OR EB15
EXTERIOR BLOWER TYPICAL DUCTWORK
CABINET
8" ROUND ELBOW
HOOD
COOKING SURFACE
HH0218A
MODEL
Q6, P3 OR P6 INTERIOR BLOWER
I
10" ROUND DUCT
24" TO 36"
ABOVE
ROOF CAP
8" ROUND DUCT
24" TO 36"
ABOVE
TYPICAL DUCTWORK
(
EXCEPT
IN-LINE BLOWER
HH0220A
MODEL ILB3, ILB6, ILB9 OR ILB11
IN-LINE BLOWER TYPICAL DUCTWORK
5
WALL CAP
10" ROUND DUCT
ILB3, 8'' ROUND DUCT)
HOOD
24" TO 36"
ABOVE
COOKING SURFACE
ROOF CAP
WALL
CAP