FAS3000
Desoutter Limited Eaton Road Hemel Hempstead Hertfordshire HP2 7DR England
Remote Interface
There are 3 sockets on the sides of the unit that can be used to interface with the FAS3000 remotely or communicate with other equipment.
ie. Solenoid, Remote Control Box, PC. etc.
RS232 Connector for software interface (Due 2003).
Recommended interface cable type: Shielded cable.
15 Pin Socket
Pin
Function
Pin 1
Power out (+24V DC)
Pin 2
Reset for cycle NOK
Pin 3
Reset for group
Pin 4
Screw OK
Pin 5
Screw NOK
Pin 6
Group OK
Pin 7
Group timer Start
Pin 8
7 pin socket, pin 5
Pin 9
Ground
Pin 10
Remote program selection
Pin 11
Remote program selection
Pin 12
Solenoid Valve
Pin 13
Not Used
Pin 14
Not Used
Pin 15
7 pin socket, pin 7
24 V DC Out – 4 Pin Socket
Pin
Function
Pin 1
Ground
Pin 2
Earth
Pin 3
Earth
Pin 4
Solenoid Valve
Reset – 2 Pin Socket
Pin
Function
Pin 1
Reset for cycle NOK
Pin 2
Power out (+24V DC)
Printed in USA
Input/Output
Mode
Output
Always +24V DC. Should only be used to power
opto coupled inputs of the microprocessor
module.
Input
+24V DC to reset
Input
+24V DC to reset
Output
+24V DC – remains on until next cycle starts
Output
+24V DC – remains on until either the NOK
cycle or group reset is enabled
Output
+24V DC – remains on until next group starts
Input
+24V DC to enable group Timer. Must be
disabled and enabled before every Group
operation (minimum interval 100ms)
-
-
-
Always 0V DC
Input
Program 1 = +24V DC
Program 2 = 0V DC
Program 3 = 0V DC
Input
Program 1 = 0V DC
Program 2 = 0V DC
Program 3 = +24V DC
Output
+24V DC when the key with the solenoid logo is
switched to on and a cycle NOK has occurred.
-
-
-
-
-
-
Input/Output
Mode
-
Always 0V DC
-
-
-
-
Output
+24V DC when the key with the solenoid logo is
switched to on and a cycle NOK has occurred.
Input/Output
Mode
Input
+24V DC to reset
Output
Always +24V DC. Should only be used to power
opto coupled inputs of the microprocessor
module.