Changing the Light Tubes
11. Press the drawer button again to close the ßatbed drawer. The top
layer of the ßatbed drawer is automatically drawn back into the
scanner, leaving the bottom layer extended. Gently press the bot-
tom layer of the ßatbed drawer into the scanner.
Changing the Light Tubes
The Flextight Progression contains four light tubes. After many hours
of use, one or more of these light tubes may require replacement.
¥ If your reßective scans are coming out black, then change the reßec-
tive tube as described in See ÒThe Flatbed Reßective TubeÓ on
page 34.
¥ If your drum scans are coming out black, then change the top trans-
parency tube as described in See ÒThe Drum TubeÓ on page 36.
¥ If your batch transparency scans are coming out black when you use
the ßatbed, then change the ßatbed transparency tube as described
in See ÒThe Flatbed Transparency TubeÓ on page 36.
¥ If your light table stops working, then change the light table tube as
described in See ÒThe Light Table TubeÓ on page 33.
The scanner contains the following types of light tubes:
¥ Drum light: Osram FM 6w/860
¥ Light table light: Osram FM 8w/860
¥ Flatbed transmission light: Osram FM 11w/860
¥ Flatbed reßective light: Osram FM 11w/860
Contact your Imacon dealer for replacements and be sure to specify
which type of tube you wish to order.