Troubleshooting

The heart rate is not shown or is shown incorrectly

Make sure the chest belt is positioned correctly and fits well.
Your skin should not be too dry or too cold. The contact areas can be slightly
moistened to improve function. Electromagnetic interference may have an adverse
effect on reception. The distance between watch and chest belt must be under
70cm. Other heart rate measuring devices within a 2m range may also cause
interference. Wireless bicycle computers may cause interference.
The batteries may be low and require replacing.

The display is unreadable / the light does not work

Replace the batteries.

Replacing the batteries

Replacing the watch battery

The battery replacement can be performed by a watch maker in addition to a
water resistance test.
To replace the battery yourself, please read the following instructions first:
Remove the screws (1, 2, 3 and 4) from the back side of the watch with a small
Phillips screwdriver. Remove the caseback and the battery sticker.
Use a small, flat tool to open the latch (5) of the battery holder. Remove the
battery and insert a fresh 3V CR2032 battery with the (+) terminal facing upwards.
Ensure that the gasket (6) is seated correctly. Close the latch of the battery holder.
Replace the battery sticker and the caseback and replace the screws.
 - 63 -

Battery low indicator

If the battery voltage on the chest belt battery drops below the voltage required for
normal operation,
TXBELT
TXGURT
LO BAT
BATT
will appear on the display. Replace the battery of the chest belt.

Replacing the chest belt battery

Use a coin to unscrew the battery
cover on the back side of the chest
belt and insert the 3V battery with the
(+) sign facing up. Screw the battery
compartment cover back into the
case.

Reset

Press SET and SEL simultaneously to totally reset the watch. All stored data will be
lost. Set up the watch as described in the chapter "Setup of the heart rate monitor".

Water resistance of the heart rate monitor

Water resistant up to 3 bar. The bar value specifies the atmospheric overpressure
which is applied during testing (DIN 8310).
SNGLTX
TXBCIN
PILE
BAT BA
battery CR2032