Please refer to the diagram located on page 5 for items D and E below. The cleaning pump intake may be clogged. Unplug the
RMU (E). Disconnect the rubber hose from the filter (D) intake fitting. Lift the RMU (E) out of the fluid, unscrew the pump intake
screen and clean it.
CLEANING PUMP STOPS
The built-in float switch will cut power to the cleaning pump when solution level has reached the minimum of 60 liters/15.85 gal.
55D600.
Top-off tank to the proper working level of at least 100 liters/26.5 gal with the fluid below that is appropriate for your Bio-Circle
Model.
INCASE OF COLD CLEANING FLUID
If the cleaning fluid is cold although the unit has been turned on for several hours, and the fluid level is topped up, please ensure the
float switch can move freely and is in the "up" position. Reset the module using the power switch, if no power switch is available
temporarily unplug the module from the power receptacle,
Bio-Circle Removable Modular Unit (RMU) Heated
If the fluid is still not being heated on model Bio-Circle Maxi 55D600 please contact the BIO-CIRCLE™ technical support line.
See pages 20-21 for contact information.
NO MORE AERATION
Aeration has stopped but air pump is still running.
Check if the air hoses are pinched somewhere along their length.
Check the air diffuser attached to the end of the air hose next to the pump and clean or replace if necessary.
Unplug the unit; remove the cover of RMU (item E pages 5) and check whether the air hose is not disconnected from the air
pump or pinched somewhere along its length.