Fitting the electric components
Warning
S Use only power units which guarantee reliable electrical isolation of the
operating voltages as per IEC 742/EN 60742/VDE 0551 with at least 4 kV
isolation resistance (Protected Extra Low Voltage PELV).
Switch power packs are permitted, providing they guarantee reliable isola-
tion in accordance with EN 60950/VDE 0805.
Please note
Long signal cables reduce the immunity to interference.
S Make sure that the length of the signal cable is always shorter than 30 m.
In this way you can avoid currents caused by electromagnetic interference.
Connect the SDE5-... as follows:
S
Pin assignment
+24 V DC power supply
Output A (out A)
0 V
*)
With cable version or if connecting socket with cable is used
type SIM-M8-3..D-... as per accessories
**)
The tightening torque is max. 0.3 Nm.
Fig. 10
Fig. 11
Festo SDE-... 0204NH English
Cable colours
brown (BN)
black (BK)
blue (BU)
SDE5-...K-...
*)
Pin
Plug assignment
1
2/4
3
Fig. 12
SDE5-...-M8-...
**)