Mounting Bolt Installation - Raytheon Commercial Laundry UW50PV Instalación Y Mantenimiento

Lavadora extractora cilíndrica de montaje permanente y velocidad variable
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
Mechanical Installation
The optional Premium Wet Clean
Note:
Module does not require permanent
attachment to the floor.

Mounting Bolt Installation

A bolt kit consisting of eight bolts is available as
an option. All UWPV machines use 3/4-10 x 8"
bolts. The bolts should be embedded in a 3500
psi minimum reinforced concrete floor that is a
minimum of 12 inches thick. Use the mounting
bolt layouts in Figure 4. (The front of the
washer-extractor is the bottom of each diagram.)
The threaded end of the bolts should extend
2 inches above the surface of the floor.
See Figure 5 for a typical installation of
individual mounting bolts.
Figure 5
22
(Continued)
Frame
Grout
P010I1A
A bolt-locator fixture or rebar frame is
available as an option. This rigid welded
assembly made of reinforcing rod and
mounting bolts is designed to be embedded
in concrete. See Figure 6.
Machine Base
Mounting
Bolt Threads
Grouting
Reinforcing
Rod
Figure 6
After the concrete has cured, proceed
as follows:
1. Place the washer-extractor adjacent to the
foundation. Do not attempt to move the
machine by pushing on the sides. Always
insert a pry bar or other device under the
bottom frame of the machine to move it.
2. Remove the wood skid by unscrewing the
carriage bolts holding the skid to the
bottom frame of the washer-extractor.
3. Place the washer-extractor carefully over
the anchor bolts. Never attempt to lift the
machine by the door handle or by pushing
on the cover panels.
4. Raise and level the washer-extractor
1/2 inch off the floor on three points, using
spacers such as nut fasteners.
P011I1A
F232051

Publicidad

Capítulos

Tabla de contenido
loading