Chemical Injection Supply System - Raytheon Commercial Laundry UW50PV Instalación Y Mantenimiento

Lavadora extractora cilíndrica de montaje permanente y velocidad variable
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation

Chemical Injection Supply System

WARNING
Wear eye and hand protection when
handling chemicals; always avoid direct
contact with raw chemicals. Read the
manufacturer's directions for accidental
contact before handling chemicals. Ensure
an eye-rinse facility and an emergency
shower are within easy reach. Check at
regular intervals for chemical leaks.
Injection Point
PVC Pipe
32
Undiluted chemical dripping can damage the
washer-extractor. Therefore, all chemical
supply dispenser pumps should be mounted
below the washer's injection point. All
dispenser tubing should also run below the
injection point. Loops do not prevent drips if
these instructions are not followed. Failure to
follow these instructions could damage the
machine and void the warranty. Figure 10
shows a typical Chemical Injection Supply
System.
SW016
Chemical Dispenser
Figure 10
Pump Outlet
P015I3A
F232051