WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are not sure about any part of these instructions, consult a qualified electrician.
• To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, a motor, or a transformer-operated appliance other than applicable fluorescent lighting.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked co/alr or cu/al.
• Clean outer surface gently with damp cloth only. DO NOT use soaps or cleaning liquids.
• No user serviceable components. DO NOT attempt to service or repair.
DESCRIPTION
The Decora Wide-View Motion Activated Light Control, Leviton Cat. No. PR150, is a passive infrared motion sensor switch designed to offer energy management capabilities to the end-user. Cat. No. PR150 operates by detecting motion
(such as body heat) within its field-of-view (area of coverage) and automatically switches lights ON. When motion is no longer detected, lights remain ON for a selected time and automatically switch OFF. Cat. No. PR150 is suitable for
indoor use only. Energy is saved with this motion switch and is ideal for any room in your home that would benefit from automatic "hands-free" light control, such as in bathrooms, bedrooms, and living areas.
Cat. No. PR150 is equipped with sensitivity and time adjustment controls, which enable the user to control the light and time settings. See "ADJUSTMENT SETTINGS" section.
FEATURES
• Cat. No. PR150 has a sensing area of coverage of 20 ft. x 20 ft. (6.1 m x 6.1 m), and a sensing angle of 150
(Figure 1).
• Adjustable light and time-delay controls are located on the front of the device (Figure 2).
• Manual override permits normal ON/OFF operation.
• LED indicator light is OFF when the switch is in automatic (AUTO) mode and flashes when motion is detected.
SPECIFICATIONS
• Not intended for use with electronic ballasts.
• Intended for use with rapid start fluorescent or incandescent lighting only.
• Installing this device requires experience with residential and commercial wiring practices. Consult local building
codes before attempting to install this device.
LOCATION / MOUNTING
Since Cat. No. PR150 responds to temperature changes, care should be taken when mounting the device.
DO NOT mount directly above a heat source, in a location where hot or cold drafts will blow directly on the sensor, or
where unintended motion (e.g., hallway traffic) will be within sensor's field-of-view.
TO INSTALL
1.
WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!
2.
Remove existing single-pole switch or dimmer installation, if applicable.
3.
Remove 3/4" (1.9 cm) of insulation from each circuit conductor. Make sure the ends of wires are straight.
4.
Connect lead wires per WIRING DIAGRAM as follows: Twist strands of each lead tightly, and with circuit conductors, push firmly into appropriate wire connector. Screw connectors on clockwise ensuring that no bare conductor shows
below the wire connectors. Secure each connector with electrical tape.
NOTE: If wire nut is provided, use to join one 14 AWG supply conductor with one 16 or 18 AWG device control lead.
5.
Gently position wires to provide room in wall box for switch.
6.
Mount device "TOP" up.
7.
Restore power at circuit breaker or fuse.
8.
Locate the adjustment controls on the front of the switch. Proceed to the "ADJUSTMENT SETTINGS" section before mounting the device in the wall box.
ADJUSTMENT SETTINGS
1. With power restored and wallplate removed, use your finger or a small screwdriver to adjust the light sensitivity
and time settings on the device as follows:
Light Level Adjustment:
• Turn the control towards the "+" sign. Lights will turn ON in lighter conditions.
• Turn the control towards the "-" sign. Lights will turn ON in less lighting conditions.
Time Selection:
• Adjust the time selector to the desired length of time the lights are to remain ON. Lights will remain ON from
15 seconds to 15 minutes after the room is vacated.
• Turn the control towards the "+" sign. Lights will remain ON up to 15 minutes.
• Turn the control towards the "-" sign. Lights will remain ON up to 15 seconds.
2. Test that the light level and time selection are as desired. If not, repeat adjustments until satisfied.
3. Mount wallplate. INSTALLATION IS COMPLETE.
TO OPERATE
Cat. No. PR150 operates in three modes:
ON:
Slide switch to the far RIGHT.
OFF:
Slide switch to the far LEFT.
AUTO:
Switch is at CENTER position.
NOTES:
• Allow 1 minute for Cat. No. PR150 to warm-up before using in auto mode.
• In AUTO mode the device will switch lights OFF in an occupied room if no motion is detected for the selected time
delay. If continuous operation is desired, select the ON position.
TROUBLESHOOTING
Lights do not switch ON when motion is detected:
• Push switch to AUTO. LED should flash when motion is detected.
• Motion is beyond sensing range, move closer to switch.
• Adjust the light level adjustment toward lighter or darker, depending on room conditions.
Lights always stay ON:
• Check that switch is in AUTO position.
• Be sure that no motion occurs in coverage area for time selected.
• Check that switch is not installed near a heat source (e.g., stove, lights, heat vents) or detecting motion from an
adjacent area (e.g., hallway traffic). If so, switch may have to be relocated.
Lights do not turn ON in AUTO or MANUAL ON modes:
• Check that switch is installed correctly.
• Check that power is ON.
• Check that light bulb is functioning.
• If applicable, check that switch on controlled unit is ON.
NOTE: If problems continue, consult a qualified electrician.
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton's
only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Mfg. Co., Inc. 201 North Service Road, Melville,
N.Y. 11747, U.S.A. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in
any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is
required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without
limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Wide View Motion Activated Light Control
Cat. No. PR150
Ratings: 500W-120VAC, 60Hz (Incandescent)
400VA-120VAC, 60Hz (Fluorescent - RAPID START MAGNETIC BALLASTS ONLY)
INDOOR USE ONLY
INSTALLATION
O
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only)
www.leviton.com
FIGURE 1
150°
20'
15'
10'
5'
SWITCH
INTERRUPTEUR-DETECTEUR / INTERRUPTOR
10'
10'
3 m
3 m
0
Wiring Diagram / Schéma de cåblage / Diagrama de Cableado
Hot (Black) / Actif (Noir) / Fase (Negro)
Line 120VAC, 60 Hz
Ligne 120 V c.a., 60 Hz
Línea 120VCA, 60 Hz
Neutral (White) / Neutre (Blanc) / Neutro (Blanco)
DI-000-PR150-22C-X0
FIGURE 2
TOP
6,1 m
(2) Control Settings
(Time and Lights)
5 m
2 réglages
(délai d'eteinte et
T
I
éclairage ambiant)
3 m
M
E
(2) Programadores
+
de Control
1,5 m
(Tiempo y Luz)
L
I
G
H
(3) Operation Modes
T
+
(Auto, OFF and ON)
(3) modes de fonctionnement
("Auto", "OFF" et "ON")
OFF
AUTO
(3) Modos de Operación
(Auto, Apagado y Encendido)
PR150
Black / Noir / Negro
Red / Rouge / Rojo
Green Ground
Terre Vert
Verde a tierra
ENGLISH
Sensor
Détecteur
Sensor
LED
Témoin
LED
Slide Switch
Bascule
Interruptor
ON
Deslizante
Black
Noir
Negro
LOAD
Charge
Carga
White
Blanc
Blanco

Publicidad

loading

Resumen de contenidos para Leviton decora PR150

  • Página 1 There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.
  • Página 2 Leviton, está libre de defectos en materiales o fabricación por un período de cinco años desde la fecha de la compra original. pendant une période de 5 ans suivant la date d’achat. La seule obligation de Leviton sera de corriger les dits défauts en réparant ou en La única obligación de Leviton es corregir tales defectos ya sea con reparación o reemplazo, como opción, si dentro de tal período de...