Error
message
Er36
NTC value is not
within its
specification
(value < 200mV or
> 4.9V; control unit
cuts off
Er31
Configuration data
incorrect
Er47
Communication
error between
TC and induction
E2
Overheating of the
induction coils
U400
Secondary voltage
of the power unit
to high (primary >
300V). Control unit
cuts off after 1 sec
releasing a
permanent tone.
E5
Error on filter
board
E6
Error on power
unit
E9
Coil temperature
sensor
defective
Description
Possible error
reason
Short-circuit or
cut-off at
NTC
Configuration of
induction
necessary
None or faulty
communication!
Control unit is
wrongly
connected.
29
Troubleshooting
Exchange control
unit
New
Configuration
Ensure that
connection cable
is plugged on
correctly and
functional.
Cooling down
necessary
Connect to
correct mains
voltage
Exchange filter
board
Exchange power
unit
Exchange
temperature
sensore