PLAN CABINET CUTOUTS
CAUTION: BEFORE CUTTING HOLE IN CABINET
!
FOR DUCTWORK, check for interference with floor
joists, wall studs, electrical wiring, or plumbing.
REAR CORNER OF
COOKTOP CUT-OUT
INSTALLATION
CENTER LINE
5 "
7
/
8
HOLE
FOR
2"
1 " X 19"
7
/
8
DUCT &
TRANSITIONS
21"
21"
centered
4"
1½"
INSIDE
CABINET FLOOR
Hole in Cabinet Floor
Dimension A
Using Flex Blower (Model
PF6 & 8" round duct straight
down through cabinet floor.)
(1½" left of installation center line)
5-5/8 inches
Use the dimensions in the above illustration to help plan how and
where to provide duct access through your cabinet. Generally, 1-7/8"
x 19" rectangular duct will be used through left, right, and back of
cabinet - while 8" round duct will be used through cabinet floor.
For left, right, or rear exhaust:
Allow at least 18" for transition and elbow or blower.
For left / right exhaust:
A 30" deep cabinet is recommended to align properly with flex
blower. Flex blower can be mounted to rear cabinet wall or to a
platform / frame (not provided) on the base of the cabinet floor.
(See flex blower instructions).
Cabinet depths of 24" to 30" are required - depending on the
type of cooking appliance.
PLAN THE WIRING
1. This downdraft blower using the Flex Blower (purchase
separately) draws 3.0 Amps and requires a 120 VAC, 60 Hz
circuit. If using a remote blower (purchase separately), the
system draws 6.0 Amps (max.) and requires a 120 VAC, 60
Hz circuit.
2. The unit has a 30 in. long power cord with a 3-pronged plug.
Plan to provide a grounded outlet in a location which will allow
the unit's power cord to reach.
3. Install electrical box according to local codes.
INSIDE
CABINET BACK
24¾"
4"
B
A
Dimension B
Using Exterior or In-Line
0
Blower & 90
Duct Elbow
(on installation center line)
7-5/8 inches
8-5/8 inches
(Model 432
(Model 418
- 8" round
- 10" round
elbow)
elbow)
Models D49M30SB • D49M36SB • D49M48SB
PREPARE THE DOWNDRAFT
Electrical panel
can be mounted
remotely.
Installations ducting through front panel opening only:
1. Place the downdraft on its back on a table or flat work surface.
2. Remove the HEX NUTS to remove the FRONT PANEL COVER.
If blower discharge is
down, electrical panel
must be relocated.
See Step 6.
Installations using FLEX BLOWER only:
(Purchase Model PF6 Flex Blower separately.)
3. Determine whether FLEX BLOWER will discharge to the left,
right, or down.
Tighten the hex nuts to secure blower in place.
FRONT PANEL COVER
#10-24 HEX
FLEX
BLOWER
#10-24 HEX
FRONT
PANEL
Page 3
(8)
NUTS
(8)
NUTS