Kohler K-3398 Manual De Instrucciones página 24

Ocultar thumbs Ver también para K-3398:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting Guide (cont.)
Symptoms
2.
Long fill cycle. Fill
valve does not
refill the tank.
The fill valve turns
3.
on and off by itself
without the toilet
being flushed.
1013091-5-B
Recommended Action
C. Check for clogged trapway or rim holes.
Clean if necessary.
D. Check for clogged soil pipe or vents. Clean
if necessary.
E. If poor flushes occur with full tanks and
clean trapway, rim holes, soil pipes, and
vents, then the pump may be the problem.
Check that the pump hoses are
undamaged and are properly installed.
F.
Power interruptions or extreme low
voltage conditions can prevent pump
operations. Check that the proper electrical
power is applied to the pump.
G. If the problem persists, replace the pump.
A. Remove dirt or obstructions from the
valve head. Flush the lines.
B. The valve inlet or supply line may be
plugged. Clear particles from valve seat.
C. The supply stop may be closed. Fully open
the supply stop valve.
D. The fill valve may be clogged. Unclog the
fill valve. If the fill valve was clogged,
install a filter in the supply line to prevent
recurring problems.
E. The float valve seal may be cracked or
split. Replace the valve assembly.
A. Clean the fill valve seat/seat washer. If no
debris is found, replace the piston/seat
washer assembly.
B. Replace the fill valve if the valve float
sinks.
C. The float operates the fill valve at too high
a level. Adjust the tank water level if it is
too high.
D. Clean the valve inlet, valve head, or
supply line. Flush the lines.
E. Either pump discharge hose may be loose
allowing water to drain from the tank into
the toilet. Ensure that both hoses are
properly connected. Contact a Kohler
Service Representative if necessary.
24
Kohler Co.

Publicidad

Tabla de contenido
loading

Tabla de contenido