2.2 REAR VIEW
Ref. 1083/38 and /48
10 11 12 13 14 15 16
10. Configuration button (PROGRAM);
11. Connector for hearing aid coil (ILA) Ref. 1168/48;
1. Trimmer for adjusting speaker volume (RV1);
13. Module connection wire connector (OUT);
14. Label with MAC ADDRESS of the device;
15. Jumper provided to connect the door state sensor;
16. Terminal board.
17. Connector for managing the device for surveillance cameras. (feature available only on door unit
Ref. 1083/39)
2.3 DESCRIPTION OF TERMINALS
Composite video signal reference (earth) (from CCTV camera or device output for surveillance
V5
cameras) (*)
V3
Composite video signal input (from CCTV camera or device output for surveillance cameras) (*)
]
PA
Hall button
]
LINE Bus line in
]
SE2
Garage relay contacts
SE-
Pedestrian electrical lock with capacitance discharge actuation negative
SE+
Pedestrian electrical lock with capacitance discharge actuation positive
(*) Terminals present only on door unit Ref. 1083/39.
2.4 DESCRIPTION OF THE WIRES FOR CONNECTING DEVICE TO SURVEILLANCE
CAMERAS (FEATURE AVAILABLE ONLY ON DOOR UNIT REF. 1083/39)
A wire is provided with the product for connecting the door unit, via the connector (17) to and the surveillance
camera control device Ref. 1083/69, for managing multiple cameras.
The camera control device Ref. 1083/69 must be set to default configuration (default setting).
R
Surveillance camera device reset: green wire
T- Surveillance camera control device reference (earth): black wire
T+ Surveillance camera device control: yellow wire
DS1083-099
Ref. 1083/39
10
11 12
13
14
Green wire (R)
Black wire (T-)
Yellow wire (T+)
T+ T- R
17
15
16
15