Using Angle Mode (Cont.)
To change to the desired unit of measure:
1. Press the
button for 2-3 seconds; "node E"
appears in the display.
2. Press the
button again "AU-1" appears in the
display.
3. Use the
buttons to cycle through the
different units of measure until you reach the
desired value.
4. Press the
button five (5) times to exit display
and proceed with applying angle load to the
fastener.
Operator can now begin to apply load to the wrench. As
the load is gradually applied to the wrench, the display will
show the operator the current degree of angle being
applied to the fastener.
As the wrench approaches the desired preset angle,
1.
the alarm will emit a steady tone and the green lights
will begin to illuminate, starting at the side nearest the
controls and ending when all green lights and the two
red lights reach the desired preset angle.
2.
After releasing the load the display will flash between
the angle value and the related torque value.
Storing Angle Values
1. After reaching the desired angle, press the
2. Pressing the
button stores the angle value.
Note: Each time a value is stored, the memory location
number increases sequentially:
n001, n002, n003 . . . etc.
NOTE: only the angle value is stored in the wrench's
memory, not the related torque.
3. Pressing the button while the angle value is
flashing allows the operator to bypass this value and
not store it.
4 . Repeat steps 1 through 2 until the desired number of
torque values have been stored.
NOTE: A maximum of 50 values can be stored in memory. The
word "FULL" appears in the display when an attempt is made
to store more than the allotted maximum.
DTW38FL, DTW12FL
1.
Solid lights and steady tone when desired
2.
button.
13
0º
angle is reached
Angle
Related Torque