Make the flue gas opening in the appliance by remov-
ing the connection cover. Use the equipment: the ten-
sion piece, the washer, the nut and bolt; see following
figure.
Only the rear covers of the side walls can be
used as a flue gas opening.
1. In the centre of the connection cover, drill a hole
with a diameter of 10 mm.
2. Place the tension piece and the bolt on the inner
side of the connection cover.
Subject to change because of technical improvements
3. Slide the washer over the bolt and tighten the nut
onto the bolt.
4. Tighten the nut by hand. Use a small amount of
grease to make it easier to turn the nut.
5. Using a ring spanner, tighten the nut so that the
connection cover breaks out.
6. Once made a flue gas opening can be closed off
again with the shut-off cover (A). This cover is not
supplied with the appliance. Use the mounting
plate (C) and M6x25 bolt (D) to fit the cover to the
appliance (B); see the following figure.
The cover (A) can be ordered as an option
using number 01.91659.020.
7. Fit the connection collar (C) to the flue gas open-
ing (D) using the two brackets supplied (E) and the
attachment materials (A) and (B); see the figures
below.
11