16. Slide Base Adjustment
(Traditional Sliders Only -
discontinued)
NOTE: ILS slider locking plungers
DO NOT require adjustment.
Some HOLLAND slide bases are equipped with
adjustable locking plungers. Adjustment should
be performed at a minimum of every 60,000
miles or if excessive movement is noticed when
driving the vehicle. To obtain proper adjustment,
follow these procedures:
1.
Loosen the lock nut and turn the
adjustment bolt counterclockwise
(Figure 43).
2.
Disengage and engage the locking
plungers. Verify that the locking
plungers have engaged properly
(Figures 44 and 45).
3.
Tighten the adjustment bolt until it
contacts the rack.
4.
Turn the adjustment bolt clockwise an
additional 1/2 turn, then tighten the
lock nut securely.
If the locking plungers DO NOT release fully
to allow the fifth wheel to slide:
Check the air cylinder for proper
operation. Replace if necessary.
Check the locking plunger adjustment
as explained above.
If a locking plunger is binding in the
plunger pocket, remove the locking
plunger using a HOLLAND TF-TLN-2500
spring compressor. Grind the top edges
of the locking plunger 1/16" (1.5 mm)
(Figure 46). Re-install and adjust the
locking plungers as explained above.
NOTE: If problems persists, contact
SAF-HOLLAND Customer Service:
888-396-6501.
XL-FW10055UM-en-US Rev E · 2018-02-15 · Amendments and Errors Reserved · © SAF-HOLLAND, Inc., SAF-HOLLAND, HOLLAND, SAF,
and logos are trademarks of SAF-HOLLAND S.A., SAF-HOLLAND GmbH, and SAF-HOLLAND, Inc.
Maintenance Procedures
Figure 43
LOCKNUT
Figure 44
UNLOCKED
(RELEASED)
RACK
Figure 45
LOCKED
(ENGAGED)
RACK
Figure 46
CHECK FOR POSSIBLE INTERFERENCE
PLUNGER
ADJUSTMENT BOLT
PLUNGER
PLUNGER
1/16"
(1.5
)
MM
20

Publicidad

loading

Este manual también es adecuado para:

Fw16 xa-161 serie