PT
Tp1
V
kW
3
°C
m
/h
22,0/23,9/24,5 970/1053/1080
0
20,4/22,2/22,8
5
18,9/20,5/21,0
10
17,4/18,8/19.3
15
15,8/17,2/17,6
20
0
15,1/13,5/11,8
13,5/14,2/14,6
5
11,8/12,5/12,8
10
10,1/10,7/11,0
15
8,3/8,8/9,0
20
PT
Tp1
V
kW
3
°C
m
/h
36,6/38,1/42,2 1615/1680/1863
0
34,2/35,6/39,4 1509/1570/1740
5
31,8/33,1/39,4 1403/1460/1618
10
29,4/30,6/33,9 1297/1349/1495
15
27,0/28,1/31,1 1191/1239/1373
20
25,7/26,7/29,6 1125/1170/1296
0
23,2/24,2/26,8 1018/1058/1173
5
20,8/21,6/24,0
10
18,3/19,1/21,1
15
18,3/19,1/21,1
20
V - Caudal de aire
PT - Capacidad de calefacción
Tp1 - Temp. de entrada de aire
Tp2 - Temp. de salida de aire
Qw
Δpw
l/h
kPa
o
Tw1 / Tw2 = 90/70
C
1,49/1,74/1,82
902/980/1004
1,31/1,52/1,59
834/906/928
1,13/1,32/1,38
766/832/852
0,97/1,13/1,18
697/757/776
0,82/0,95/0,99
o
Tw1 / Tw2 = 70/50
C
662/699/716
0,79/0,87/0,91
590/623/639
0,64/0,71/0,74
517/546/560
0,51/0,56/0,58
441/467/479
0,38/0,42/0,44
362/384/395
0,27/0,3/0,31
Qw
Δpw
l/h
kPa
o
Tw1 / Tw2 = 90/70
C
4,7/5,0/6,1
4,1/4,4/5,4
3,6/3,9/4,7
3,1/3,4/4,1
2,7/2,9/3,5
o
Tw1 / Tw2 = 70/50
C
2,6/2,8/3,3
2,1/2,3/2,8
910/946/1049
1,7/1,9/2,3
801/833/924
1,4/1,5/1,8
801/833/924
1,4/1,5/1,8
Tw1 - Temp. de entrada de agua
Tw2 - Temp. de salida de agua
Qw - Caudal de agua caliente
Δ pw - presión de agua
MU-EMP-10-W2F
Tp2
PT
°C
kW
33/31/30
18,9/20,0/20,5
35/34/33
17,3/18,3/18,8
38/36/36
15,7/16,6/17,0
40/39/39
14,1/14,9/15,3
43/42/41
12,5/13,1/13,5
21/21/20
10,7/11,6/12,0
24/23/23
8,8/9,7/10,0
27/26/26
6,6/7,6/7,8
29/29/28
3,8/4,0/4,0
31/31/31
3,1/3,2/3,3
MU-EMP-15-W2F
Tp2
PT
°C
kW
36,0/35,0/33,0 31,2/32,5/36,0
38,5/38,0/35,5 28,8/29,9/33,2
41,0/40,5/38,5 26,3/27,4/30,4
43,5/43,0/41,0 23,9/24,9/27,5
46,0/45,5/44,0 21,5/22,3/24,7
25,5/24,5/23,0 20,1/20,9/23,2
28,0/27,5/26,0 17,6/18,3/20,3
30,5/30,0/28,5 15,1/15,7/17,4
33,0/32,5/31,5 12,4/13,0/14,4
33,0/32,5/31,5 9,66/10,1/11/3
V - Air flow
PT - Heating capacity
Tp1 - Inlet air temperature
Tp2 - Outlet air temperature
8
Qw
Δpw
l/h
kPa
o
Tw1 / Tw2 = 80/60
C
832/878/900
1,16/1,28/1,34
761/803/824
0,99/1,09/1,14
691/729/747
0,83/0,91/0,95
619/654/670
0,68/0,75/0,78
547/578/592
0,54/0,6/0,63
o
Tw1 / Tw2 = 70/40
C
464/508/521
0,43/0,51/0,53
386/424/436
0,31/0,37/0,39
289/329/341
0,19/0,23/0,25
167/173/174
0,07/0,08/0,08
137/141/142
0,05/0,05/0,05
Qw
Δpw
l/h
kPa
o
Tw1 / Tw2 = 80/60
C
1370/1425/1580
3,6/3,8/4,6
1264/1314/1457
3,1/3,3/4,0
1157/1203/1334
2,6/2,8/3,4
1050/1092/1210
2,2/2,4/2,8
943/981/1086
1,8/1,9/2,3
o
Tw1 / Tw2 = 70/40
C
876/911/1010
1,7/1,8/2,2
767/798/885
1,3/1,4/1,7
656/683/758
1,0/1,1/1,3
542/565/628
0,7/0,8/0,9
421/440/492
0,5/0,5/0,6
Tw1 - Inlet water temperature
Tw2 - Outlet water temperature
Qw - Heating water stream
Δ
pw - water pressure
Tp2
°C
27/26/25
29/28/28
32/31/31
35/34/34
37/37/36
16/15/15
18/18/17
20/19/20
21/20/21
25/24/24
Tp2
°C
31,0/30,0/28,0
33,5/32,5/31,0
36,0/35,0/33,5
38.5/37,5/36,0
41,0/40,0/39,0
20,0/19,5/18,0
22,5/22,0/21,0
25,0/24,5/23,5
27,0/27,0/26,0
29,5/29,0/28,5