5 - Basic Set-up Examples
Setting-up a Square Wave Clock Signal
Press the soft-key labelled LoLvl - the current low level voltage appears in the edit box.
•
Use the numeric keypad to enter a new level. Press 0
•
Press the soft-key labelled V to confirm a low level of 0.0 volts.
•
Turn the Output On
Press Output 1 key to turn the channel 1 output On.
•
The Output 1 key illuminates orange to indicate the on state