Rail Mounted Load Positioner Installation
For proper and safe installation of the unit on a rail system refer to Installation and Maintenance Manual for
that rail system.

Air System

The supply air must be clean and free from water or moisture. 6.9 bar/690 kPa (100 psi) at the unit is required
to provide rated capacity. Do not exceed 6.9 bar/690 kPa.
• Do not exceed 6.9 bar/690 kPa (100 psi) inlet pressure. Do not use a lubricator of any kind. Oil will
damage internal components.
Air Lines
The inside diameter of the unit air
supply lines must not be smaller than
10 mm (3/8 in.) based on a
maximum of 30 m (100 ft.) between
the air supply and the unit. Contact
the factory for recommended air line
sizes for distances greater than 30 m
(100 ft.). Before making final
connections, all air supply lines
should be purged before connecting
to unit inlet. Supply lines should be
as short and straight as installation
conditions will permit. Long
transmission lines and excessive use
of fittings, elbows, tees, globe
valves, etc. cause a reduction in
pressure due to restrictions and
surface frictions in the lines. If
quick-disconnect fittings are used at
the inlet of the unit, they must have
at least a 10 mm (3/8 in.) passage.
Use of smaller fittings will reduce
performance.
Air Line Filter
It is recommended that an air line
strainer/filter be installed as close as
practical to the unit air inlet port.
The strainer/filter should provide 10
micron filtration and include a
moisture trap. Clean the strainer/
filter monthly to maintain its
operating efficiency.
To maintain dry air, the frequency for draining the filter should also be based on the condition of the air
supply. We suggest the filter be drained weekly at first. Depending on air supply condition, a proper filter
drain schedule should be established.
Moisture in Air Lines
Moisture that reaches the unit through the supply lines is the chief factor in determining the length of time
between service overhauls. Moisture traps can help to eliminate moisture. Other methods, such as an air
receiver which collects moisture before it reaches the unit controls or an aftercooler at the compressor that
cools the air prior to distribution through the supply lines, are also helpful.
WARNING
Capacity in kg (lbs)
Wire
*
005
= 22 (50)
032 = 147 (325)
*015 = 68 (150)
*035 = 158 (350)
020 = 90 (200)
050 = 500 (227)
032 = 147 (325)
065 = 294 (650)
*035 = 158 (350)
*070 = 317 (700)
040 = 181 (400)
100 = 453 (1000)
050 = 227 (500)
065 = 294 (650)
*070 = 317 (700)
080 = 362 (800)
100 = 453 (1000)
130 = 589 (1300)
*140 = 365 (1400)
200 = 907 (2000)
Model No.
MW
Series
MW = Wire Rope
MC = Chain
Travel
060 = 60 inches (1525 mm).
Travel distance is determined by
series and capacity, and is not a
variable option. Refer to Model
No. in Specification Chart.
Example: MW005060
3
Chain
B = Basic - no controls
P = Pendant control
S
= Single balance
E = Hi, low, no load
*Not available
with Down Stop
option.
005
060
00
00
SR =
V2 =
HM =
TR =
AT
A1 =
A2 =
K1 =
K2 =
E4 =
E8 =
GB =
Control
control
control
Options
S = Down
Stop
S
S
Suspension
=
No Suspension
IRS2/S3
Valu Trak
Hook Mount
T-Rail/I-Beam
=
ZRAT
ZRA1
ZRA2
KBK1
KBK2
ETA-4
ETA-8
Gorbel