Permissible Configurations; Impermissible Configurations; Reviewing The Valve Zone Conversion; Conversion Documentation - Emerson AVENTICS AES PROFINET IO Descripción Del Sistema

Acoplador de bus aes/controladores de válvula av
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 90
28
29 30 43 20 24 22 23 30 44
UA
P
S1
Fig. 16: Creating sections with two pneumatic supply plates and one electrical
supply plate
28
Bus coupler
30
Pneumatic supply plate
20
Base plate, 2x
24
Valve driver board, 4x
23
Valve driver board, 3x
42
Valve position for pressure regulator
35
Electrical supply plate
61
Valve
S2
Section 2
P
Pressure supply
UA
Power supply
The valve system in Fig. 16 consists of three sections:
Table 21: Example valve system, consisting of three sections
Section
Components
Section 1
• Pneumatic supply plate (30)
• Three base plates, 2x (20), and one base plate, 3x (21)
• Valve driver boards, 4x (24), 2x (22), and 3x (23)
• 9 valves (61)
Section 2
• Pneumatic supply plate (30)
• Four base plates, 2x (20)
• Two valve driver boards, 4x (24)
• 8 valves (61)
• AV-EP base plate, single pressure control
• AV-EP pressure regulator
Section 3
• Electrical supply plate (35)
• Two base plates, 2x (20), and one base plate, 3x (21)
• Supply plate (38), valve driver board, 4x (24), and valve driver board, 3x
(23)
• 7 valves (61)

12.5.2 Permissible configurations

AES-
D-BC-
PNIO
UA
P
A
B
B
Fig. 17: Permissible configurations
You can expand the valve system at all points designated with an arrow:
• After a pneumatic supply plate (A)
• After a valve driver board (B)
• At the end of a section (C)
• At the end of the valve system (D)
To simplify your documentation and configuration, we recommend
that you expand the valve system on the right end (D).

12.5.3 Impermissible configurations

Fig. 18 displays the configurations that are not permissible. You may not:
• Split a 4x or 3x valve driver board
AVENTICS™ AES PROFINET IO | R412018140-BAL-001-AH | English
42
41
35 38 61
P
UA
A
S2
S3
29
Transition plate
43
Long bridge card
21
Base plate, 3x
22
Valve driver board, 2x
44
Short bridge card
41
Integrated AV-EP circuit board
38
Supply board
S1
Section 1
S2
Section 3
A
Single pressure control working con-
nection
P
UA
C A
B
C
• Mount more than 64 valves (128 solenoid coils)
• Integrate more than 8 AV-EPs
• Integrate more than 32 electrical components.
Some configured components have multiple functions and therefore count as
multiple electrical components.
Table 22: Number of electrical components per component
Configured component
Valve driver boards, 2x
Valve driver boards, 3x
Valve driver boards, 4x
Pressure regulators
Electrical supply plate
UA-OFF monitoring board
AES-
D-BC-
PNIO
UA
P
Fig. 18: Examples for impermissible configurations

12.5.4 Reviewing the valve zone conversion

Following the conversion of the valve zone, use the following checklist to de-
u
termine whether you have complied with all rules.
• Have you mounted at least 4 valve positions after the first pneumatic supply
plate?
• Have you mounted a maximum of 64 valve positions?
• Have you integrated no more than 32 electrical components? Note that an
AV-EP pressure regulator corresponds to three electrical components.
• Have you mounted at least two valves after every pneumatic or electrical sup-
ply plate that marks the start of a new section?
• Have you always installed the valve driver boards to be in line with the base
plate limits, i.e.
– One base plate, 2x, is installed with one valve driver board, 2x,
– Two base plates, 2x, are installed with one valve driver board, 4x,
– One base plate, 3x, is installed with one valve driver board, 3x,
• Have you integrated no more than 8 AV-EPs?
If you have answered "Yes" to all these questions, you may proceed with the doc-
umentation and configuration of the valve system.

12.5.5 Conversion documentation

B
D
PLC configuration key
After a conversion, the PLC configuration key printed on the right end plate is no
longer valid.
1. Correct the PLC configuration key or cover it with a new label and write the
new PLC configuration key on the end plate.
2. Always document all changes to your configuration.
Mat. no.
After a conversion, the material number (MNR) on the right end plate is no longer
valid.
Mark the material number so that it is clearly visible that the unit no longer
u
corresponds to its original condition on delivery.
Number of electrical components
P
UA
AES-
AES-
D-BC-
D-BC-
PNIO
PNIO
UA
P
UA
1
1
1
3
1
1
UA
P
UA
42