STEP 2 Connect the hot water line
• The water line pressure must be between 20 psi and 120 psi (140–830 kPa).
• Make sure that the water temperature is delivered between 120 °F and 149 °F (49-
60 °C). Exceeding this limit may cause the dishwasher to malfunction.
• Make sure that the circuit breaker and water valve is turned off before connecting the
water supply line to the dishwasher.
• Make sure the water line is properly connected. Wrap Teflon tape around every
connection and joint to prevent water leaks.
3⁄16" (5 mm)
Inlet valve
90° elbow
DACOR_DW9500M_DD68-00197A-01_EN.indd 13
Water valve
Hot water line
fitting
1. Insert the 3⁄4" 90-degree fitting into the
inlet valve. Tighten the fitting until it
points towards the water-hose channel
in the base of the dishwasher. Do not
overtighten.
2. Connect the hot water line to the fitting.
3. If you want to secure the dishwasher
to the side wall for extra stability,
bend the brackets of the left and right
housings by referring to the figure.