MASTERBUS FUNCTIONS
6 MASTERBUS FUNCTIONS
6.1 MASTERBUS MENUS
This chapter describes the MasterBus functions
available with the AC Power Analyser.
Menu
Description
First setup (Monitoring)
Language
Language setting of the AC Power Analyser.
NOTE: the language of the display may be
different from this setting.
System mode
Kind of system to use the AC Power Analyser for. Shore
Shore
Shore input power
Generator
Generator input power
Inverter
Inverter output power
Nominal voltage
Selectable grid voltage. This setting also
determines the shore fuses range to select.
Current transfer
The coil windings ratio determines the current
transfer. Needed is the number of primary
windings.
Primary
Number of primary windings selectable
Secondary
Number of secondary windings. 5 windings
fixed value
Generator power
Maximum generator power (in Generator
mode only)
Inverter power
Maximum generator power (in inverter mode
only)
Done
Confirmation that you are ready, doing the
First setup
First setup (Configuration)
Name
Name of this device
Relay name
Name of the relay
Relay
Relay type: normal open or normal closed
Done
Primary setup done button to confirm primary
setup. After primary setup a new menu
appears, depending on the system mode
setting.
10
These depend on the system mode selected during the
first setup.
Default
English
—
—
—
230V AC
—
100
5.0 fixed
3.5 kW
0.8 kW
AC Pwr Analyser
—
Normal open
—
February 2011 / AC Power Analyser / EN
Range
See Specifications
Shore, Generator, Inverter
120V AC , 230V AC
—
1–250, resolution 1
—
0–46 kW
0–46 kW
Any max 12 character name
Max 12 characters
Normal open, normal closed
—